CEM DT-8868 Infrared Thermometer
Short Description:
Price-savvy shoppers in Dubai, UAE rejoice – CEM DT-8868 now available for purchase. Grab yours now!
CEM DT-8868 Infrared Thermometer
The CEM DT-8868 Infrared Thermometer is an advanced non-contact temperature measuring device designed for industrial and professional use. It uses infrared technology to measure surface temperatures from a distance, providing accurate readings quickly and easily.
The CEM DT8868 Infrared Thermometer measures temperatures from -50°C to 1850°C (-58°F to 3362°F), making it suitable for a wide range of applications. It offers high accuracy, typically ±1% of the reading or ±1°C (±2°F), whichever is greater. Additionally, its emissivity can be adjusted from 0.10 to 1.00, allowing for accurate measurements on different surface types.
CEM DT-8868 Key Features
- User selectable ºC or ºF
- Dual Laser targeting
- Automatic Data Hold
- Auto Power Off
- White Backlit LCD Display
- Overrange indication
- High Temperature
- Max, Min, DIF, AVG record
- High / low alarm, Trigger lock
- Adjustable emissivity
- Reading memory (8868/8869/8868H/8869H)
- Type K input
- USB interface
CEM DT-8868 Specifications
Specifications | DT-8867H | DT-8868 | DT-8869 | DT-8868H | DT-8869H |
IR Temp. Range | -50ºC to 1650ºC/
-58ºF to 3002ºF |
-50ºC to 1200ºC/
-58ºF to 2192ºF |
-50ºC to 1600ºC/ -58ºF to 2912ºF | -50ºC to 1850ºC/ -58ºF to 3362ºF | -50ºC to 2200ºC/ -58ºF to 3992ºF |
Response Time | Less than 150ms | Less than 150ms | Less than 150ms | Less than 150ms | Less than 150ms |
Resolution | 0.1º up 1000º, 1º over 1000º | 0.1º up 1000º, 1º over 1000º | 0.1º up 1000º, 1º over 1000º | 0.1º up 1000º, 1º over 1000º | 0.1º up 1000º, 1º over 1000º |
Basic Accuracy (IR) | ±1.0% of reading | ±1.0% of reading | ±1.0% of reading | ±1.0% of reading | ±1.0% of reading |
Optical Resolution | 30:1 Distance to Spot size | 50:1 Distance to Spot size | 50:1 Distance to Spot size | 50:1 Distance to Spot size | 50:1 Distance to Spot size |
Emissivity | Adjustable 0.10~1.0 | Adjustable 0.10~1.0 | Adjustable 0.10~1.0 | Adjustable 0.10~1.0 | Adjustable 0.10~1.0 |
Type K Temp. Range | -50ºC to 1370ºC/
-58ºF to 2498ºF |
-50ºC to 1370ºC/
-58ºF to 2498ºF |
-50ºC to 1370ºC/
-58ºF to 2498ºF |
-50ºC to 1370ºC/
-58ºF to 2498ºF |
-50ºC to 1370ºC/
-58ºF to 2498ºF |
Basic Accuracy (TK) | ±1.5% of reading | ±1.5% of reading | ±1.5% of reading | ±1.5% of reading | ±1.5% of reading |
Readings memories | 99 | 99 | 99 | 99 |
Specifications
Specifications | DT-8867H | DT-8868 | DT-8869 | DT-8868H | DT-8869H |
IR Temp. Range | -50ºC to 1650ºC/
-58ºF to 3002ºF |
-50ºC to 1200ºC/
-58ºF to 2192ºF |
-50ºC to 1600ºC/ -58ºF to 2912ºF | -50ºC to 1850ºC/ -58ºF to 3362ºF | -50ºC to 2200ºC/ -58ºF to 3992ºF |
Response Time | Less than 150ms | Less than 150ms | Less than 150ms | Less than 150ms | Less than 150ms |
Resolution | 0.1º up 1000º, 1º over 1000º | 0.1º up 1000º, 1º over 1000º | 0.1º up 1000º, 1º over 1000º | 0.1º up 1000º, 1º over 1000º | 0.1º up 1000º, 1º over 1000º |
Basic Accuracy (IR) | ±1.0% of reading | ±1.0% of reading | ±1.0% of reading | ±1.0% of reading | ±1.0% of reading |
Optical Resolution | 30:1 Distance to Spot size | 50:1 Distance to Spot size | 50:1 Distance to Spot size | 50:1 Distance to Spot size | 50:1 Distance to Spot size |
Emissivity | Adjustable 0.10~1.0 | Adjustable 0.10~1.0 | Adjustable 0.10~1.0 | Adjustable 0.10~1.0 | Adjustable 0.10~1.0 |
Type K Temp. Range | -50ºC to 1370ºC/
-58ºF to 2498ºF |
-50ºC to 1370ºC/
-58ºF to 2498ºF |
-50ºC to 1370ºC/
-58ºF to 2498ºF |
-50ºC to 1370ºC/
-58ºF to 2498ºF |
-50ºC to 1370ºC/
-58ºF to 2498ºF |
Basic Accuracy (TK) | ±1.5% of reading | ±1.5% of reading | ±1.5% of reading | ±1.5% of reading | ±1.5% of reading |
Readings memories | 99 | 99 | 99 | 99 |
You must be logged in to post a review.