Fluke 1550C Insulation Tester -5kv
Short Description:
The Fluke 1550C FC 5 kV Digital Insulation Tester performs digital insulation testing up to 5 kV, and makes data collection easy through the Fluke Connectâ„¢ wireless app.
Product purchase
Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868
10
People watching this product now!
Terms of sending goods ›
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
Fluke 1550C Insulation Resistance Tester
Fluke 1550C Insulation Tester performs digital insulation testing up to 5 kV, and makes data collection easy through the Fluke Connectâ„¢ wireless app. Remote operation lets you spend as little time as possible in potentially hazardous zones. Real-time trending shows a live graph on your phone, rather than a hard-to-read set of changing values.
And you can create reports quickly, using pre-designed templates that you can customize with company logos. It’s the perfect tool for preventive or predictive maintenance programs designed to identify potential equipment failures before they occur. It comes with a three-year warranty and CAT IV 600 V safety rating.
Benefits of Fluke 1550C Insulation Tester Calibration
Calibrating your Fluke 1550C Insulation Tester offers numerous benefits:
- Accuracy: Calibration ensures that your measurements are precise, reducing errors and inaccuracies.
- Compliance: It helps you meet industry standards and regulatory requirements.
- Quality Assurance: Calibrated instruments contribute to the overall quality and safety of your work.
- Longevity: Regular calibration extends the lifespan of your Fluke 1550C, protecting your investment.
- Reliability: Calibrated instruments are more reliable, reducing the risk of equipment failure.
Fluke 1550C Insulation Tester specifications:
Fluke 1550c specifications are
Specifications | ||
Maximum voltage between any terminal and earth ground | 600 V | |
Safety | IEC 61010-1: Pollution Degree 2 | |
IEC 61010-2-033: CAT III 600V | ||
Fuse for A input | 11 A, 1000 V FAST Fuse (Fluke PN 803293) | |
Display | Digital: 6,000 counts, updates 4 per second | |
Bar graph | 33 segments, updates 32 per second | |
Operating temperature | -10°C to +50°C | |
Storage temperature | -40°C to +60°C | |
Battery type | 9 volt Alkaline, IEC 6LR61 | |
Battery life | 400 hours typical, without backlight | |
Accuracy Specifications | ||
DC millivolts | Range/resolution | 600.0 mV / 0.1 mV |
Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
DC volts | Range/resolution | 6.000 V / 0.001 V |
60.00 V / 0.01 V | ||
600.0 V / 0.1 V | ||
Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
Auto volts | Range/resolution | 600.0 V / 0.1 V |
Accuracy | 2.0% + 3 (DC, 45 Hz to 500 Hz) | |
4.0% + 3 (500 Hz to 1 kHz) | ||
AC millivolts¹ True RMS | Range/resolution | 600.0 mV / 0.1 mV |
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) | |
2.0% + 3 (500 Hz to 1 kHz) | ||
AC volts¹ True RMS | Range/resolution | 6.000 V / 0.001 V |
60.00 V / 0.01 V | ||
600.0 V / 0.1 V | ||
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) | |
2.0% + 3 (500 Hz to 1 kHz) | ||
Continuity | Range/resolution | 600 Ω / 1 Ω |
Accuracy | Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of | |
500 μs or longer. | ||
Ohms | Range/resolution | 600.0 Ω / 0.1 Ω |
6.000 kΩ / 0.001 kΩ | ||
60.00 kΩ / 0.01 kΩ | ||
600.0 kΩ / 0.1 kΩ | ||
6.000 MΩ / 0.001 MΩ | ||
Accuracy | 0.9% + 1 | |
Range/resolution | 40.00 MΩ / 0.01 MΩ | |
Accuracy | 5% + 2 | |
Diode test | Range/resolution | 2.00 V / 0.001 V |
Accuracy | 0.9% + 2 | |
Capacitance | Range/resolution | 1000 nF / 1 nF |
10.00 μF / 0.01 μF | ||
100.0 μF / 0.1 μF | ||
9999 μF / 1 μF | ||
100 μF to 1000 μF | ||
Accuracy | 1.9% + 2 | |
Range/resolution | > 1000 μF | |
Accuracy | 5% + 20% | |
Lo-Z capacitance | Range | 1 nF to 500 μF |
Accuracy | 10% + 2 typical | |
AC amps True RMS (45 Hz to 500 Hz) | Range/resolution | 6.000 A / 0.001 A |
10.00 A / 0.01 A | ||
Accuracy | 1.5% + 3 | |
20 A continuous overload for 30 seconds max | ||
DC amps | Range/resolution | 6.000 A / 0.001 AÂ Â 10.00 A / 0.01 A |
Accuracy | 1.0% + 3 | |
20 A continuous overload for 30 seconds max | ||
Hz (V or A input)² | Range/resolution | 99.99 Hz / 0.01 Hz |
999.9 Hz / 0.1 Hz | ||
9.999 kHz / 0.001 Hz | ||
50.00 kHz / 0.01 Hz | ||
Accuracy | 0.1% + 2 | |
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. | ||
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. | ||
2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. | ||
2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F. | ||
Mechanical and General Specifications | ||
Size | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) | |
Weight | 550 g | |
Warranty | 3 years |
Specification table
Specifications | ||
Maximum voltage between any terminal and earth ground | 600 V | |
Safety | IEC 61010-1: Pollution Degree 2 | |
IEC 61010-2-033: CAT III 600V | ||
Fuse for A input | 11 A, 1000 V FAST Fuse (Fluke PN 803293) | |
Display | Digital: 6,000 counts, updates 4 per second | |
Bar graph | 33 segments, updates 32 per second | |
Operating temperature | -10°C to +50°C | |
Storage temperature | -40°C to +60°C | |
Battery type | 9 volt Alkaline, IEC 6LR61 | |
Battery life | 400 hours typical, without backlight | |
Accuracy Specifications | ||
DC millivolts | Range/resolution | 600.0 mV / 0.1 mV |
Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
DC volts | Range/resolution | 6.000 V / 0.001 V |
60.00 V / 0.01 V | ||
600.0 V / 0.1 V | ||
Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
Auto volts | Range/resolution | 600.0 V / 0.1 V |
Accuracy | 2.0% + 3 (DC, 45 Hz to 500 Hz) | |
4.0% + 3 (500 Hz to 1 kHz) | ||
AC millivolts¹ True RMS | Range/resolution | 600.0 mV / 0.1 mV |
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) | |
2.0% + 3 (500 Hz to 1 kHz) | ||
AC volts¹ True RMS | Range/resolution | 6.000 V / 0.001 V |
60.00 V / 0.01 V | ||
600.0 V / 0.1 V | ||
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) | |
2.0% + 3 (500 Hz to 1 kHz) | ||
Continuity | Range/resolution | 600 Ω / 1 Ω |
Accuracy | Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of | |
500 μs or longer. | ||
Ohms | Range/resolution | 600.0 Ω / 0.1 Ω |
6.000 kΩ / 0.001 kΩ | ||
60.00 kΩ / 0.01 kΩ | ||
600.0 kΩ / 0.1 kΩ | ||
6.000 MΩ / 0.001 MΩ | ||
Accuracy | 0.9% + 1 | |
Range/resolution | 40.00 MΩ / 0.01 MΩ | |
Accuracy | 5% + 2 | |
Diode test | Range/resolution | 2.00 V / 0.001 V |
Accuracy | 0.9% + 2 | |
Capacitance | Range/resolution | 1000 nF / 1 nF |
10.00 μF / 0.01 μF | ||
100.0 μF / 0.1 μF | ||
9999 μF / 1 μF | ||
100 μF to 1000 μF | ||
Accuracy | 1.9% + 2 | |
Range/resolution | > 1000 μF | |
Accuracy | 5% + 20% | |
Lo-Z capacitance | Range | 1 nF to 500 μF |
Accuracy | 10% + 2 typical | |
AC amps True RMS (45 Hz to 500 Hz) | Range/resolution | 6.000 A / 0.001 A |
10.00 A / 0.01 A | ||
Accuracy | 1.5% + 3 | |
20 A continuous overload for 30 seconds max | ||
DC amps | Range/resolution | 6.000 A / 0.001 AÂ Â 10.00 A / 0.01 A |
Accuracy | 1.0% + 3 | |
20 A continuous overload for 30 seconds max | ||
Hz (V or A input)² | Range/resolution | 99.99 Hz / 0.01 Hz |
999.9 Hz / 0.1 Hz | ||
9.999 kHz / 0.001 Hz | ||
50.00 kHz / 0.01 Hz | ||
Accuracy | 0.1% + 2 | |
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. | ||
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. | ||
2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. | ||
2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F. | ||
Mechanical and General Specifications | ||
Size | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) | |
Weight | 550 g | |
Warranty | 3 years |
4.6
Rated 4.6 out of 5
12 reviews
Rated 5 out of 5
7
Rated 4 out of 5
4
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
12 reviews for Fluke 1550C Insulation Tester -5kv
Clear filters
Add a review Cancel reply
You must be logged in to post a review.
Related Products
Kyoritsu KEW 3552 Digital Insulation / Continuity Tester
Rated 5.00 out of 5
(1)
In stock
Kyoritsu Kew 3431 Analogue Insulation Tester
Rated 5.00 out of 5
(1)
In stock
Kyoritsu 3005A Digital Insulation Continuity Tester
Rated 5.00 out of 5
(1)
In stock
Kyoritsu 3166
In stock
Samuel –
Fluke has always been my best
martin spielberg –
What are the key features and benefits of the Fluke 1550C FC 5 kV Digital Insulation Tester?
Store manager behruzshy2015 –
The Fluke 1550C FC 5 kV Digital Insulation Tester is a robust and versatile tool for testing insulation resistance in electrical systems. It stands out with its 5 kV output, digital display for accurate measurements, and Fluke Connect compatibility for wireless data transfer. Safety features like automatic discharge and voltage alarms enhance user security. The device offers precision, long battery life, and the ability to measure voltage, resistance, and capacitance. Its rugged design ensures durability in industrial settings. Overall, the 1550C FC is a trusted choice for professionals in the electrical and industrial fields, providing reliable measurements, data management, and safety.
We sent more info about Fluke 1550C FC 5 kV Digital Insulation Tester to your email
ahmedalhassan123@gmail.com (verified owner) –
fluke 1550c is reliable and accurate
fatimaali1998@gmail.com (verified owner) –
top notch build quality
mohammedsultan159951@gmail.com (verified owner) –
fluke 1550c is easy to use
mariamsaeed1988@gmail.com (verified owner) –
excellent data storage
rashidkhalid2005@gmail.com (verified owner) –
great for high-voltage testing
laylaalmansoori123@gmail.com (verified owner) –
saves time and effort
omarsheikh@gmail.com (verified owner) –
versatile and comprehensive
sarahamiri1127@gmail.com (verified owner) –
a bit pricey but worth it
zayedsalem (verified owner) –
exceptional battery life
yasminaabdel (verified owner) –
excellent customer support