Fluke 1736/B Three-Phase Power Quality Logger
Short Description:
Fluke 1736B Includes:
- 1736 Power Logger
- Power supply
- Voltage test leads
- Alligator clips (x4)
- Soft case
- Energy Analyze Plus software
- Line cords
- Color coding set
Product purchase
Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868
13
People watching this product now!
Terms of sending goods ›
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
Fluke 1736B Portable Power Logger
The Fluke 1736/B Portable Power Logger, in its basic version, is designed without current probes and is ideal for conducting energy studies and basic power quality logging. This device is compatible with the Fluke Connect® mobile app and desktop software, which enables real-time data access for critical power quality and energy decisions. It’s capable of capturing and logging over 500 power quality parameters, offering detailed insights to optimize system reliability and energy savings.
Fluke 1736/B features a user-friendly interface, flexible setup options, and an intelligent measurement verification function to reduce measurement errors by digitally verifying and correcting common connection issues. Its comprehensive logging ability allows for more than 20 separate sessions to be stored, capturing important parameters like dips, swells, and inrush currents with event waveform snapshot and high-resolution RMS profiles. The logger’s bright, color touch screen facilitates in-field analysis and data checks, enhancing its usability.
For data management, the Fluke 1736 B fluke power quality meter allows easy downloading directly to a USB flash drive or remotely via the Fluke Connect app, making it flexible for various working environments. The device comes with Fluke Energy Analyze Plus software for in-depth analysis and automated reporting, aiding in the efficient communication of findings and problem-solving to optimize system reliability and savings.
This version of the Fluke 1736B is particularly suitable for applications where detailed energy consumption and power quality analysis are essential, but where the specific use case does not require the immediate use of current probes. However, it’s important to note that for current measurements, separate current probes would need to be acquired.
Fluke 1736 B Features
- Versatile, three-phase power loggers for conducting energy, load, and power quality studies.
- Automatically capture and log voltage, current, power, harmonics, and associated power quality values, and capture dips, swells, and inrush currents with event waveform snapshots and high-resolution RMS profiles.
- Convenient instrument powering directly from the measured circuit
- Download and analyze every detail of energy consumption and power quality state of health with our automated reporting.
Fluke 1736/B Specifications:
Electrical Specifications of Fluke 1738B | |
Power Supply | |
Voltage range | 100 V to 500 V using a safety plug input when powering from the measurement circuit |
100 V to 240 V using standard power cord (IEC 60320 C7) | |
Power consumption | Maximum 50 VA (max. 15 VA when powered using IEC 60320 input) |
Efficiency | ≥ 68.2% (in accordance with energy efficiency regulations) |
Maximum no-load consumption | < 0.3 W only when powered using IEC 60320 input |
Mains power frequency | 50/60 Hz ±15% |
Battery | Li-ion 3.7 V, 9.25 Wh, customer-replaceable |
On-battery runtime | Four hours in standard operating mode, up to 5.5 hours in power-saving mode |
Charging time | < 6 hours |
Data Acquisition | |
Resolution | 16-bit synchronous sampling |
Sampling frequency | 10.24 kHz at 50/60 Hz, synchronized to mains frequency |
Input signal frequency | 50/60 Hz (42.5 to 69 Hz) |
Circuit types | 1-φ, 1-φ IT, Split phase, 3-φ delta, 3-φ wye, 3-φ wye IT, 3-φ wye balanced, 3-φ Aron/Blondel (2-element delta), 3-φ delta open leg, Currents only (load studies) |
Data storage | Internal flash memory (not user-replaceable) |
Memory size | Typical 10 logging sessions of 8 weeks with 1-minute intervals and 500 events¹ |
¹The number of possible logging sessions and logging period depends on user requirements. | |
Basic Interval | |
Measured parameters | Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy |
Averaging interval | User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min |
Averaging time min/max values | Voltage, Current: Full cycle RMS updated every half cycle (URMS1/2 according to IEC61000-4-30 Aux, Power: 200ms |
Demand Interval (Energy Meter Mode) | |
Measured parameters | Energy (Wh, varh, VAh), PF, maximum demand, cost of energy |
Interval | User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off |
Power Quality Measurements | |
Measured parameter | Voltage, frequency, unbalance, voltage harmonics, THD V, current, harmonics, THD A, TDD |
Averaging interval | 10 min |
Individual harmonics | 2nd to 50th harmonic |
Total harmonic distortion | Calculated on 50 harmonics |
Events | Voltage: dips, swells, interruptions, current: inrush current |
Triggered recordings | Full cycle RMS updated every half cycle of voltage and current (Urms1/2 according to IEC61000-4-30) |
Waveform of voltage and current (1738) | |
Standards Compliance | |
Harmonics | IEC 61000-4-7: Class 1 |
IEEE 519 (short time harmonics) | |
Power quality | IEC 61000-4-30 Class S, IEC62586-1 (PQI-S device) |
Power | IEEE 1459 |
Power quality compliance | EN50160 (for measured parameters) |
Interfaces | |
USB-A | File transfer via USB flash drive, firmware updates Max. current: 120 mA |
WiFi | File transfer and remote control via direct connection or WiFi infrastructure |
Bluetooth | Read auxiliary measurement data from Fluke Connect® 3000 series modules (requires 1738 or 1736 upgrade option) |
USB-mini | Data download device to PC |
Voltage Inputs | |
Number of inputs | 4 (3 phases and neutral) |
Maximum input voltage | 1000 Vrms, CF 1.7 |
Input impedance | 10 MΩ |
Bandwidth (-3 dB) | 42.5 Hz – 3.5 kHz |
Scaling | 1:1 and variable |
Measurement category | 1000 V CAT III/600 V CAT IV |
Current Inputs | |
Number of inputs | 4, mode selected automatically for attached sensor |
Input voltage | Clamp input: 500 mVrms/50 mVrms; CF 2.8 |
Rogowski coil input | 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range |
Range | 1 A to 150 A/10 A to 1500 A with thin flexible current probe i17XX-flex1500 12″ |
3 A to 300 A/30 A to 3000 A with thin flexible current probe i17XX-flex3000 24″ | |
6 A to 600 A/60 A to 6000 A with thin flexible current probe i17XX-flex6000 36″ | |
40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-EL | |
Bandwidth (-3 dB) | 42.5 Hz – 3.5 kHz |
Scaling | 1:1 and variable |
Auxiliary Inputs | |
Number of inputs | 2 |
Input range | 0 to ±10 V dc, 1reading/s |
Scale factor | Format: mx + b (gain and offset) user configurable |
Displayed units | User configurable (7 characters, for example, °C, psi, or m/s) |
Wireless Connection | |
Number of inputs | 2 |
Supported modules | Fluke Connect® 3000 series |
Acquisition | 1 reading/s |
Environmental Specifications | |
Operating temperature | -10 °C to +50 °C (14 °F to 122 °F) |
Storage temperature | -20 °C to +60 °C (-4 °F to 140 °F), with battery: -20 °C to +50 °C (-4 °F to 122 °F) |
Operating humidity | 10 °C to 30 °C (50 °F to 86 °F) max. 95% RH |
30 °C to 40 °C (86 °F to 104 °F) max. 75% RH | |
40 °C to 50 °C (104 °F to 122 °F) max. 45% RH | |
Operating altitude | 2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV) |
Storage altitude | 12,000m |
Enclosure | IP50 in accordance with EN60529 |
Vibration | MIL-T-28800E, Type 3, Class III, Style B |
Safety | IEC 61010-1 |
IEC Mains Input: Overvoltage Category II, Pollution Degree 2 | |
Voltage Terminals: Overvoltage Category IV, Pollution Degree 2 | |
IEC 61010-2-031: CAT IV 600 V / CAT III 1000 V | |
Electromagnetic compatibility | EN 61326-1: Industrial CISPR 11: Group 1, Class A |
Korea (KCC): Class A Equipment (industrial broadcasting and communication equipment) | |
USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103 | |
Temperature coefficient | 0.1 x accuracy specification/°C |
General Specifications | |
Color LCD display | 4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch panel |
Warranty | Instrument and power supply: Two years (battery not included) |
Accessories: one-year | |
Calibration cycle: two years | |
Dimensions | Instrument: 19.8 cm x 16.7 cm x 5.5 cm (7.8 in x 6.6 in x 2.2 in) |
Power supply: 13.0 cm x 13.0 cm x 4.5 cm (5.1 in x 5.1 in x 1.8 in) | |
Instrument with power supply attached: 19.8 cm x 16.7 cm x 9 cm (7.8 in x 6.6 in x 3.5 in) | |
Weight | Instrument: 1.1 kg (2.5 lb) |
Power supply: 400 g (0.9 lb) | |
Tamper protection | Kensington lock slot |
i17xx-flex 1500 12″ Flexible Current Probe Specifications | |
Measuring range | 1 to 150 A ac/10 to 1500 A ac |
Nondestructive current | 100 kA (50/60 Hz) |
Intrinsic error at reference condition* | ±0.7% of reading |
Accuracy 173x + iFlex | ±(1% of reading + 0.02% of range) |
Temperature coefficient over operating temperature range | 0.05% of reading/°C 0.09% of reading/°F |
Working voltage | 1000 V CAT III, 600 V CAT IV |
Probe cable length | 305 mm (12 in) |
Probe cable diameter | 7.5 mm (0.3 in) |
Minimum bending radius | 38 mm (1.5 in) |
Output cable length | 2 m (6.6 ft) |
Weight | 115 g |
Probe cable material | TPR |
Coupling material | POM + ABS/PC |
Output cable | TPR/PVC |
Operating temperature | -20 °C to +70 °C (-4 °F to 158 °F) temperature of conductor under test shall not exceed 80 °C (176 °F) |
Temperature, non-operating | -40 °C to +80 °C (-40 °F to 176 °F) |
Relative humidity, operating | 15% to 85% non-condensing |
IP rating | IEC 60529:IP50 |
Warranty | One-year |
Rated 0 out of 5
0 reviews
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
Be the first to review “Fluke 1736/B Three-Phase Power Quality Logger” Cancel reply
You must be logged in to post a review.
Related Products
Kyoritsu 6315-01 Power Quality Analyzer Kit with Bluetooth
Rated 5.00 out of 5
In stock
Kyoritsu 6315-00 Power Quality Analyzer with Bluetooth
Rated 5.00 out of 5
In stock
Fluke VR1710 Single Phase Power Quality Recorder & Voltage Recorder
Rated 5.00 out of 5
In stock
Call for Price
Fluke 434 II and 435 II Power Quality and Energy Analyzers
Rated 5.00 out of 5
In stock
Call for Price