Fluke 6004 Portable Power Analyzer four-channel
Short Description:
Fluke 6004 Includes:
- Portable power analyzer
- Power supply adapter
- Power cord
- Test leads, 1.5 m, (4) red, (4) black, (8) blue
- Alligator clips, (4) red, (4) black, (8) blue
- USB (mini B) cable
- RS-485/synchrony adapter (3.81mm, black, 3 pin)
- USB Flash Drive for PC SW and User Manual
- Soft case
Product purchase
Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868
17
People watching this product now!
Terms of sending goods ›
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
Fluke 6004 Portable Power Analyzer
The Fluke NORMA 6004 Portable Power Analyzer is a versatile tool designed for making precision power measurements in a variety of settings. Fluke 6004 features four voltage and current input channels, allowing for detailed analysis of power systems. Fluke 6004 offers a 0.1% measurement accuracy and a bandwidth of 500kHz. Notably portable and battery-powered, it’s ideal for field use, providing up to 10 hours of operation on a single charge. This model is specifically tailored for electrical measurements and does not include speed and torque measurement capabilities.
Fluke Power Analyzer Features
- Measure voltage, current, active power, reactive power, apparent power, power factor and harmonics with associated values
- Get accurate, precise results with 0.1% measurement accuracy and a 500kHz bandwidth
- Take precision power measurements almost anywhere – highly portable, battery powered analyzer weighing only 3.5kg with up to 10 hours of battery life
Fluke 6004 Specifications:
Inputs | Norma 6003 | 3 Voltage + 3 Current |
Norma 6003+ | 3 Voltage + 3 Current + 1 Motor | |
Norma 6004 | 4 Voltage + 4 Current | |
Norma 6004+ | 4 Voltage + 4 Current + 1 Motor | |
Sample rate | 200ks/s | |
Measurement update rate | 100ms, 200ms, 500ms, 1s | |
Dimensions (H * W * L) | 298mm x 215m x 96mm | |
Weight | 3.5 kg (7.7 lbs) | |
Display | 5.7 inch, TFT LCD, 640×480 | |
Operating temperature | -10 °C to +50 °C | |
Storage temperature | -30 °C to +60 °C | |
Operating humidity | Non-condensing (< 10 °C ) ≤ 90 % RH (at 10 °C to 30 °C) ≤ 75 % RH (at 30 °C to 40 °C) ≤ 45 % RH (at 40 °C to 50 °C) |
|
Operating altitude | 2000m | |
Storage altitude | 12000m | |
Ingress protection | IP 50 (Terminals mated) according to IEC 60529: | |
Battery | BP 291, 10.8V/5000mAh, 54Wh IEC 62133, UN38.3 Operating time: 10 Hours (on battery) |
|
Safety | IEC 61010-1: Pollution Degree 2 IEC 61010-2-030: CAT IV 600V, CAT III 1000 V |
|
EMC | IEC 61326-1: Industrial IEC 61326-2-2 |
|
Warranty | 1 Year | |
Communication Interface | USB/RS485 | |
Dual Analyzer Synchronization Mode | Able to extend to 6, 7 or 8 channels (using multiple instruments) | |
PC Software | Fluke Power Analyzer software | |
Storage Capacity | 32GB | |
Data trend storage rate | As per display rate | |
Main Function | Meter, Scope, Harmonic, Phasor, Trend | |
Measuring Parameters | RMS, DC Component, AC Component, Rectified Mean, Peak Value, Peak-Peak, Crest Factor, Form Factor, Fundamental Component, Fundamental Content, Harmonic Distortion, Harmonic Content, Harmonic Factor for voltages and currents, Active Power, Reactive Power, Apparent Power, Power Factor, Phase Shift, Efficiency, Impedance, Electric Energy, Charge/Discharge capacity (Ah), Frequency, Motor Speed, Torque, Mechanical Power, Mechanical Energy, Summation function |
Electrical Specifications | |
Voltage | |
Range | 10 V, 100 V, 1000 V |
Crest Factor | CF ≤ 2 |
Maximum Voltage | 10 % overload |
Input Impedance | 2M Ω/10pF (Typical) |
Temperature Coefficient | 0.05 * (Spec)/k |
Bandwidth | 1000V range: 500kHz; 100V range: 200 kHz; 10V range:100 kHz |
CMRR | 120 dB @ 50/60 Hz |
Accuracy (% reading + % range) | |||
Range | 1000 V | 100 V | 10 V |
DC | 0.1 + 0.1 | 0.1 + 0.1 | 0.1 + 0.2 |
AC (10Hz to 1kHz) | 0.1 + 0.1 | 0.1 + 0.1 | 0.1 + 0.2 |
AC (10kHz) | 5 + 0.5 | 5 + 0.5 | 5 + 0.5 |
Current | |||
Crest Factor | CF ≤ 2 | ||
Temperature Coefficient | 0.05 x (Spec)/k | ||
Overload capacity | 10 % overload | ||
CMRR | 120 dB @ 50/60 Hz | ||
Shunt (current input) | |||
Measuring Range | 0.1 A, 1 A, 10 A | ||
Input Impedance | 0.025 Ω (Typical) | ||
Bandwidth | 10 A range: 500 kHz; 1 A range: 200 kHz; 0.1 A range: 100 kHz | ||
BNC (voltage input) | |||
Range | 0.1 V, 1 V, 10 V | ||
Input Impedance | 100k Ω/100pF (Typical) | ||
Bandwidth | 10 V range: 500 kHz; 1 V range: 200 kHz; 0.1 V range: 100 kHz |
Accuracy (% reading + % range) | ||||||
Range | 10 A | 1 A | 0.1 A | 10 V | 1 V | 0.1 V |
DC | 0.1 + 0.2 | 0.1 + 0.5 | 0.1+2 | 0.1+0.1 | 0.1+0.2 | 0.1+1 |
AC (10Hz to 1kHz) | 0.1+0.1 | 0.1+0.2 | 0.1+1 | 0.1+0.1 | 0.1+0.1 | 0.1+0.5 |
AC (10kHz) | 5+1 | 5+1 | 5+1 | 5+1 | 5+1 | 5+1 |
Motor Module (Torque and Speed) | ||||||
Voltage Range | ± 10 V dc, 10 % overload | |||||
Voltage Channels | 2 | |||||
Input Impedance | 1.1M Ω (Typical) | |||||
Accuracy at dc | 0.1 % range + 0.1 % reading | |||||
Pulse Channels | 3 | |||||
Pulse Logic High Threshold | 2 V (Typical) | |||||
Pulse Logic Low Threshold | 0.8 V (Typical) | |||||
Maximum Pulse Frequency | 100 kHz | |||||
Motor Module (Torque and Speed) | ||||||
Frequency Accuracy | 0.05 % range + 0.05 % reading | |||||
Harmonics | 100 (50Hz/60Hz) | |||||
Calculation method | FFT/Interpolation |
Rated 0 out of 5
0 reviews
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
Be the first to review “Fluke 6004 Portable Power Analyzer four-channel” Cancel reply
You must be logged in to post a review.
Related Products
Kyoritsu 6315-03 Power Quality Analyzer Kit with Bluetooth
Rated 5.00 out of 5
In stock
Reviews
Clear filtersThere are no reviews yet.