Fluke iSee TC01A Mobile Thermal Camera
Price-savvy shoppers in Dubai, UAE, don’t miss out! Grab the Fluke iSee TC01A now. High-quality tools at affordable rates await you.
MME Shopping Event
Hurry and get discounts on Most of MME Products up to 20%
AED 1,749 Original price was: AED 1,749.AED 1,600Current price is: AED 1,600. (excl.VAT)
Fluke iSee TC01A Mobile Thermal Camera
The Fluke iSee TC01A Mobile Thermal Camera features an infrared resolution of 256 x 192 pixels, offering detailed image quality. It can operate in temperatures ranging from -10°C to 550°C, making it versatile for various applications. The camera provides a thermal sensitivity of 50 mk (0.05°C), and its accuracy is ±2% or ±2°C. Additionally, it has a 25 Hz frame rate for smooth video recording and supports customizable color palettes. It’s also equipped with IP54 ingress protection and is designed to be durable, capable of withstanding a 1-meter drop.
Fluke iSee TC01A Key Features
- 256 x 192 pixels, detailed image quality
- Up to 550 ℃, suitable to use in many applications
- ±2% or ±2 °C accuracy to ensure reliable results
- 25Hz frame rate for smooth video recording
- Customize image view with more than 10 standard or custom color palettes
- Never miss any detail with real-time high and low temperature capture
- Adjustable emissivity to apply with different materials
- Comprehensive temperature analysis for spot, line and area, supported with professional thermal imaging mobile software
- Real-time temperature alarm for timely response of the abnormal condition
- Automatic time-lapse capture mode for unattended operation
- Share and manage images and videos in real-time, for fast and efficient communication
- Up to 1 meter drop test, IP56 (TC01B)/IP54 (TC01A) ingress protection, adhering to the Fluke durability and quality
Fluke iSee TC01A Specifications
TC01A | TC01B | |
Performance specifications | ||
IR resolution | 256 x 192 | |
Pixel size | 12 μm | |
Temperature range | -10 ℃ to 550 ℃ | -20 ℃ to 550 ℃ |
Temperature accuracy | ± 2% of rdg or ± 2 °C, whichever is greater (@ 23 °C ± 5 °C ambient temperature) | |
Temperature measurement distance | 0.25 to 5 m(* -20 ℃ to 10 ℃, only for 0.25 to 3 m) | |
Frame rate | 25 Hz | |
Warm-up time | 1 minute | |
Focal length | Fixed focal length: 3.2 mm | |
Shutter mode | Built-in automatic shutter | |
Thermal sensitivity (NETD) | 50 mK | |
Spectral range | 8 to 14 μm | |
Field of view (H x V) | 56° x 42° | |
Spatial resolution | 3.81 mrad | |
General Specifications | ||
USB Interface | Type C | Lightning |
Operating temperature | 0℃ to 40 ℃ | |
Storage temperature | -30 °C to 60 °C | |
Operating humidity | 10% to 90% RH, non-condensing | |
Power consumption | 350 mW (Typical) | 200 mW (Typical) |
Drop test | 1 m | |
Ingress protection | IEC 60529: IP54 (with Type C cover) | IEC 60529: IP56 |
Operating altitude | 2000 m | |
Storage altitude | 12000 m | |
Dimensions (L x W x H) | 60 x 33.5 x 11.2 mm | |
Weight | 22 g |
You must be logged in to post a review.
Brand
Fluke
Fluke Corporation
Since its founding in 1948, Fluke has helped define and grow a unique technology market, providing testing and troubleshooting capabilities that have grown to mission critical status in manufacturing and service industries. Every new manufacturing plant, office, hospital, or facility built today represents another potential customer for Fluke products. From industrial electronic installation, maintenance and service, to precision measurement and quality control, Fluke tools help keep business and industry around the globe up and running. Typical customers and users include technicians, engineers, metrologists, medical-device manufacturers, and computer network professionals — people who stake their reputations on their tools, and use tools to help extend their personal power and abilities.Specifications
TC01A | TC01B | |
Performance specifications | ||
IR resolution | 256 x 192 | |
Pixel size | 12 μm | |
Temperature range | -10 ℃ to 550 ℃ | -20 ℃ to 550 ℃ |
Temperature accuracy | ± 2% of rdg or ± 2 °C, whichever is greater (@ 23 °C ± 5 °C ambient temperature) | |
Temperature measurement distance | 0.25 to 5 m(* -20 ℃ to 10 ℃, only for 0.25 to 3 m) | |
Frame rate | 25 Hz | |
Warm-up time | 1 minute | |
Focal length | Fixed focal length: 3.2 mm | |
Shutter mode | Built-in automatic shutter | |
Thermal sensitivity (NETD) | 50 mK | |
Spectral range | 8 to 14 μm | |
Field of view (H x V) | 56° x 42° | |
Spatial resolution | 3.81 mrad | |
General Specifications | ||
USB Interface | Type C | Lightning |
Operating temperature | 0℃ to 40 ℃ | |
Storage temperature | -30 °C to 60 °C | |
Operating humidity | 10% to 90% RH, non-condensing | |
Power consumption | 350 mW (Typical) | 200 mW (Typical) |
Drop test | 1 m | |
Ingress protection | IEC 60529: IP54 (with Type C cover) | IEC 60529: IP56 |
Operating altitude | 2000 m | |
Storage altitude | 12000 m | |
Dimensions (L x W x H) | 60 x 33.5 x 11.2 mm | |
Weight | 22 g |
Specifications
Related Products
Fluke TiS55+ Thermal Camera: Best one!
In stock
FLUKE PTi120 Compact Thermal Camera
In stock
Reviews
Clear filtersThere are no reviews yet.