Fluke PVT900A Gas Flow Analyzer Ventilator Tester

Fluke PVT900A Gas Flow Analyzer Ventilator Tester stands as a pinnacle in biomedical testing equipment. Its versatility, precision in ultra-low flow conditions, and user-friendly interface make it an indispensable tool for healthcare professionals. With the ever-increasing demands on medical equipment, having a reliable and accurate testing instrument like the PVT900A is crucial for ensuring patient safety and the overall effectiveness of healthcare systems.

SKU: 72340
Brand:Fluke

Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868

We are not Supporting COD Payments Terms Outside UAE

12 People watching this product now!

Fluke PVT900A Gas Flow Analyzer Ventilator Tester

The Fluke PVT900A Gas Flow Analyzer Ventilator Tester is a cutting-edge device designed for meticulously testing gas flow equipment, particularly focusing on high accuracy in ultra-low flow and ultra-critical applications. This versatile instrument is a crucial tool for professionals in the biomedical field, ensuring the optimal performance and safety of ventilators and other medical gas flow systems.

Key Features

The Fluke PVT900A boasts various features that make it an indispensable asset in the healthcare industry. Its ability to test various types of gas flow equipment sets it apart, providing a comprehensive solution for biomedical professionals. The device excels in ultra-low flow scenarios, where precision is paramount, ensuring that ventilators and anesthesia equipment operate at peak efficiency.

Versatility in Testing

One of the standout features of the PVT900A is its versatility in testing both gas flow and anesthesia equipment. This dual functionality streamlines testing processes, offering a consolidated solution for professionals working with different types of medical equipment. Integrating an anesthesia tester enhances the device’s utility, making it an all-encompassing tool for biomedical testing needs.

Precision in Ultra-Low Flow

The Fluke PVT900A is engineered to deliver unparalleled precision, especially in ultra-low flow conditions. This is crucial in medical settings where even the slightest deviation from optimal performance can have severe consequences. The device’s capability to maintain accuracy in these challenging conditions ensures that healthcare professionals can rely on the results for critical decision-making.

User-Friendly Interface

Despite its advanced capabilities, the Fluke PVT900A features a user-friendly interface, making it accessible to a wide range of healthcare professionals. The intuitive design and easy-to-navigate menu system contribute to the device’s usability, allowing users to perform complex tests easily. This user-centric approach enhances testing processes’ efficiency and reduces operators’ learning curve.

Fluke PVT900A Gas Flow Analyzer Ventilator Tester Specifications:

  • Battery life hours: 8 hrs
  • Charge time in hours: 5 hrs, typical
  • Memory: internal memory
  • Connection type: USB, Micro-B device port
  • Weight: 3.6 lb (1.6 kg)
  • Product dimensions (L x W x H): 23.9 x 18.8 x 7.6 cm  (9.4 x 7.4 x 3 in)
  • Display: 7 in (17.8 cm)
  • Single full-range channel
  • Ultra-low flow ports: ±750 ml/min
  • Ultra-low pressure port 0 to 10 mbar

Flow

  • Range: 0 to ±200 slpm
    • Accuracy: ±2.0% of rdg or 0.04 slpm
    • Range: 200 to 300 slpm, -200 to -300 slpm, -22 to – 14 slpm, +7.5 to +9.5 slpm
    • Accuracy: ±2.5% of rdg
  • Ultra-low flow channel
    • Range: ±750 ml/min
    • Accuracy: ±1.7 % or 0.01 slpm
  • Volume
    • Range: ±100 l
    • Accuracy: ±2.0 % or 0.02 l

Pressure

  • High pressure
    • Range: -0.8 to 10 bar
    • Accuracy: ±1 % or ±0.007 bar
  • Differential low pressure
    • Range: ±160 mbar
    • Accuracy: ±0.5 % or ±0.1 mbar
  • Ultra-low pressure
    • Range: 0 to 10 mbar
    • Accuracy: ±1 % or ±0.01 mbar
  • Airway pressure
    • Range: ±160 mbar
    • Accuracy: ±0.5 % or ±0.1 mbar
  • Barometric pressure
    • Range: 550 to 1240 mbar
    • Accuracy: ±1 % or ±5 mbar

Other

  • Temperature
    • Range: 0 to 50 °C
    • Accuracy: ±0.5 °C
    • Resolution: 0.1 °C
  • Humidity
    • Range: 0 to 100 % RH
    • Accuracy: ±3 % RH (20 to 80 % RH) ±5 % RH (20< or >80 % RH)
  • Oxygen
    • Range: 0 to 100 %
    • Accuracy: ±1 %

Environmental

  • Operating temp: 10 °C to 40 °C
  • Storage temp: -20 °C to 60 °C
  • Operating humidity: 10 to 90 % non-condensing
  • Storage humidity: 5 to 95 % non-condensing
0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Fluke PVT900A Gas Flow Analyzer Ventilator Tester”

Datasheet

Datasheet

Datasheet