MEGGER MRCT RELAY AND Current Transformer Tester
The Megger Mrct Relay And Current Transformer is a lightweight, robust, portable unit used to perform demagnetization, ratio, saturation, winding resistance, polarity, phase deviation, and insulation tests on current transformers.
Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868
We are not Supporting COD Payments Terms Outside UAE
The Megger MRCT is a lightweight, robust, portable unit used to perform demagnetization, ratio, saturation, winding resistance, polarity, phase deviation, and insulation tests on current transformers. The MRCT automatically calculates ratio errors, saturation curves, and knee points.
The MRCT provides a microprocessor-controlled variable voltage and current output and precision instrumentation for automatically testing single and multi-ratio CTs, reducing testing time and increasing productivity. The MRCT will directly connect to multi-radio CT’s and perform all tests – saturation, ratio and polarity, winding resistance, and insulation – on all taps with the push of a button and without changing leads.
The MRCT can be controlled via Megger’s Smart Touch View Interface (STVI) controller, a full color, high resolution, LCD touch screen that allows the user to perform manual and automatic testing quickly and easily using the manual test screen, as well as using pre-constructed test routines.
The large display permits the user to easily read all pertinent data while the test is being performed and provides the ability to view the current transformer’s saturation curve. The unit can also be configured to come without a Megger STVI and can be controlled via a laptop with Megger’s PowerDB software.
Megger MRCT Specifications
- Input: 100 to 132 V or 200 to 264 V, 1ø, 50 or 60 Hz, 15 A max.
- Voltage: Continuously variable in three ranges: 0 to 30 V at 5.0 A max (15 minutes on, 5 minutes off) 0 to 300 V at 1.0 A max (15 minutes on, 5 minutes off) 300 to 2000 V at 1.0 A max (5 minutes on, 5 minutes off)
- Current
- Output Current: Power Max V/Duty Cycle
- 30 Amperes: 200 VA (282 peak) 6.67 V rms (15 minutes on, 5 minutes off)
- 60 Amperes : 600 VA 90 cycles
- Resolution : 0.0000 to 1.9999/19.999/199.99/1999.9
- Ranges : 0 to 2/20/200/2000 V
- Accuracy : ±0.5% of reading typical±1.0% of reading typical max
- Ranges : 0 to 0.35/2.0/20.0/200.0/600.0 V
- Resolution: 0.0001 to 1.9999/19.999/199.9/600 V
- Accuracy : ±0.02% of reading and ±.02% range typical ±0.05% of reading and ±05% range maximum
- Ranges : 0 to 2/20.0/200.0/2000.0 V
- Resolution: 0.0000 to 19.999/199.9/1999.9 V
- Accuracy : 0 to 999.9 V ±0.02% of reading and ±.02%
- range : typical ±0.05% of reading and ±.05% range maximum1000 to 2000 V ±0.08% of reading and ±.08%
- range typical ±0.2% of reading and ±0.2% range maximum
- Ranges: 0.0 to 1.0/10.0/60.0 A
- Resolution : .001/.01
- Range: 0.0000 to1.0 A
- Accuracy : ±0.08% of reading ±.08% range typical : ±0.2% of reading ±0.2% range maximum
You must be logged in to post a review.
SPECIFICATIONS
Category | Feature | Specification |
---|---|---|
Input | Power Input | 100 to 132 V or 200 to 264 V, 1ø, 50 or 60 Hz, 15 A max. |
Output Voltage | 0 to 30 V | 5.0 A max (15 minutes on, 5 minutes off) |
0 to 300 V | 1.0 A max (15 minutes on, 5 minutes off) | |
300 to 2000 V | 1.0 A max (5 minutes on, 5 minutes off) | |
Current | Output Current | Power Max V/Duty Cycle |
30 Amperes | 200 VA (282 peak) 6.67 V rms (15 minutes on, 5 minutes off) | |
Instrumentation | Voltmeters | – |
Output | Resolution: 0.0000 to 1.9999/19.999/199.99/1999.9 Ranges: 0 to 2/20/200/2000 V Accuracy: ±0.5% of reading typical, ±1.0% of reading max |
|
Primary Voltage Measurement | Ranges | 0 to 0.35/2.0/20.0/200.0/600.0 V |
Resolution | 0.0001 to 1.9999/19.999/199.9/600 V | |
Accuracy | ±0.02% of reading and ±0.02% range typical, ±0.05% of reading and ±0.05% range max | |
Secondary Voltage Measurement | Ranges | 0 to 2/20.0/200.0/2000.0 V |
Resolution | 0.0000 to 19.999/199.9/1999.9 V | |
Accuracy | 0 to 999.9 V ±0.02% of reading and ±0.02%, 1000 to 2000 V ±0.08% of reading and ±0.08% max | |
Ammeter | Output | Ranges: 0.0 to 1.0/10.0/60.0 A Resolution: .001/.01 |
Excitation Curve Testing | Range: 0.0000 to 1.0 A Accuracy: ±0.08% of reading ±0.08% range typical, ±0.2% of reading ±0.2% range max |