Rated 0 out of 5
(0)
- Rated measurement current: 5 A AC
- Max. measurement current: Continuous 50 A (45 to 66 Hz)
- Output rate: 10 mV AC/ A
- Amplitude accuracy: ±0.3 % rdg. ±0.02 % f.s.
- Phase accuracy: ±2° (45 Hz to 5 kHz)
- Measurable conductor diameter: φ 15 mm (0.59 in) or less
- Operating temperature and humidity: 0°C to 50°C (32°F to 122°F), 80% RH or less (no condensation)
Rated 0 out of 5
(0)
- Measures leak current in AC 10 A (50/60 Hz)
- Max. allowable input: 10 A of continuous input
- Rated output current: AC 100 mV/A
- Amplitude accuracy: ±1.0 % rdg. ±0.005 % f.s.
- Phase accuracy: ±5 ° (at 50 Hz or 60 Hz)
- Measurable conductor: Insulated conductor
- Core diameter: φ 30 mm (1.18 in)
Rated 0 out of 5
(0)
- 100:1 Division ratio with ±3% accuracy at 100 VDC
- 100:1 Division ratio with +3%, -7% accuracy at 1000 VDC
- 5 kV peak input voltage for reliable measurements
- 100 MΩ input impedance for minimal signal loss
- DC to 200 MHz frequency range for accurate measurements
- 7 pF or less input capacitance for reduced noise
- 1.5 m cable length for convenient use
Rated 0 out of 5
(0)
- Rated measurement current: 500 A AC
- Max. measurement current: Continuous 550 A (45 to 66 Hz)
- Output rate: 1 mV AC/ A
- Amplitude accuracy: ±0.3% rdg. ±0.01% f.s.
- Phase accuracy: ±0.5° (45 Hz to 5 kHz)
- Measurable conductor diameter: φ 46 mm (1.81 in) or less
- Operating temperature and humidity: 0°C to 50°C (32°F to 122°F), 80% RH or less (no condensation)
Rated 0 out of 5
(0)
- Rated measurement current: 100 A AC
- Max. measurement current: Continuous 130 A (45 to 66 Hz)
- Output rate: 1 mV AC/ A
- Amplitude accuracy: ±0.3 % rdg. ±0.02 % f.s.
- Phase accuracy: ±1° (45 Hz to 5 kHz)
- Measurable conductor diameter: φ 15 mm (0.59 in) or less
- Operating temperature and humidity: 0°C to 50°C (32°F to 122°F), 80% RH or less (no condensation)
Rated 0 out of 5
(0)
- Rated primary current: AC 10 A (for leak current measurement, 50/60 Hz)
- Max. allowable input: Max. 30 A of continuous input
- Rated output current: AC 100 mV/A
- Amplitude accuracy: ±1.0 % rdg. ±0.05 % f.s.
- Phase accuracy: ±3 ° (at 50 Hz or 60 Hz)
- Frequency characteristics: 40 Hz to 5 kHz: ± 3% (Add to amplitude accuracy)
- Measurable conductor: Insulated conductor
- Core diameter: φ 40 mm (1.57 in)
Rated 0 out of 5
(0)
- Advanced waveform analysis with 256 channels analog and 128 channels logic
- Waveform display, X-Y display, and Digital value display
- Parameter calculation and search functions
- Supports various file formats including .MEM, .REC, and .RMS
- Print functions including image file output and hard copy
- Compatible with Windows 11, 10/8/7
Rated 0 out of 5
(0)
- LAN Communicator for Hioki devices
- 9333 model
- Downloadable license cards available
- Easy communication with Hioki devices
- Compact design for easy use
- Reliable performance in various environments
- Wide range of applications in electrical measurement
Rated 0 out of 5
(0)
- Detect voltage signals or relay contact signals with the Hioki 9327 Logic Probe.
- 4-channel input with common ground between unit and channels.
- Switchable input for digital or contact input.
- High input resistance for accurate signal detection.
- Compact design with carrying case and accessories.
- Reliable measurement for electrical signal detection.
- Perfect for electrical engineers and technicians.
Rated 0 out of 5
(0)
- DC mode: Waveform monitor output, DC to 10 MHz ±3 dB
- AC mode: Detection of power line surge noise, 1 kHz to 10 MHz ±3 dB (Low frequency cut-off frequency 1 kHz ± 300 Hz)
- RMS mode: Rectified RMS output of DC and AC voltages, DC, 40 Hz to 100 kHz
- Response speed: 200 ms or less (400 V AC)
- Max. allowable input: 2000 V DC, 1000 V AC
- Max. rated voltage to earth: When using the Grabber Clip L9243: 1000 V AC/DC (CAT II), When using alligator clip: 1000 V AC/DC (CAT II), 600 V AC/DC (CAT III)
- Output: Voltage division ratio: 1/1000, BNC terminal (DC/AC/RMS 3-mode selectable output)
- DC amplitude accuracy: ±1 % f.s. (1000 V DC or less), ±3 % f.s. (2000 V DC or less) (f.s.=2000 V DC)
- RMS amplitude accuracy: ±1 % f.s. (DC, 40 Hz to 1 kHz), ±4 % f.s. (1 kHz to 100 kHz) (f.s.=1000 VAC)
- Input resistance, capacity: H-L: 9 MΩ, approx 10 pF (C at 100 kHz), H-case, L-case: 4.5 MΩ, approx 20 pF (C at 100 kHz)
- Power supply: +5 V to +12 V, less than 300 mA (DC jack OD 5.5 mm [0.22 in.], ID 2.1 mm [0.08 in.])
- Dimensions and mass: 70 mm (2.76 in.)W × 150 mm (5.91 in.)H × 25 mm (0.98 in.)D, 285 g (10.1 oz.), Cord length: Input 46 cm (1.51 ft.), Output 1.3 m (4.27 ft.)
- Included accessories: Alligator clips ×1 (red/black set), Grabber Clip L9243 ×1 (red/black set), Carrying case C0203 ×1, Instruction manual ×1
Rated 0 out of 5
(0)
- Rated current: 20 A to 1000 A AC, 6 ranges
- Accuracy: ±3 % rdg. ±0.2 % f.s. (45 to 66 Hz)
- Frequency characteristics: Add to amplitude accuracy for frequencies from 40 to 1 kHz: ± 1 % rdg.
- Output rate: 0.2 V AC f.s. (f.s. = setting rage)
- Max. allowable input: 1000 A rms continuous (all ranges)
- Max. rated voltage to earth: 600 Vrms (50/60 Hz, CAT III)
- Core diameter: φ55 mm (2.17 in), or 20 mm (0.79 in) × 80 mm (3.15 in) busbar
- Dimensions and mass: 100 mm (3.94 in)W × 224 mm (8.82 in)H × 35 mm (1.38 in)D, 600 g (21.2 oz)
Rated 0 out of 5
(0)
- Rated current: 10 A to 500 A AC, 6 ranges
- Accuracy: ±1.5% rdg. ±0.1% f.s. (45 to 66 Hz)
- Frequency characteristics: Add to amplitude accuracy : ± 1% rdg. Add to phase accuracy : ± 2.5° for frequencies from 40 Hz to 3 kHz
- Output rate: 0.2 V AC f.s. (f.s. = setting rage)
- Max. allowable input: 150 A rms continuous (10/20/50 A ranges) 400 A rms continuous (100/200 A ranges) 650 A rms continuous (500 A range)
- Max. rated voltage to earth: 600 V rms (50 Hz/60 Hz, CAT III)
- Core diameter: φ46 mm (1.81 in)
- Dimensions and mass: 78 mm (3.07 in) W × 188 mm (7.40 in) H × 35 mm (1.38 in) D, 420 g (14.8 oz)
- Cord length: 3 m (9.84 ft)
Rated 0 out of 5
(0)
- Rated current: 10 A to 500 A AC, 6 ranges
- Accuracy: ±2 % rdg. ±1 % f.s. (45 to 66 Hz)
- Frequency characteristics: Add to amplitude accuracy for frequencies from 40 to 1 kHz
- Output rate: 0.2 V AC f.s.
- Max. allowable input: 150 A rms continuous
- Max. rated voltage to earth: 600 Vrms (50/60 Hz, CAT III)
- Core diameter: φ46 mm (1.81 in)
- Dimensions and mass: 78 mm (3.07 in)W × 188 mm (7.40 in)H × 35 mm (1.38 in)D, 420 g (14.8 oz)
Rated 0 out of 5
(0)
- High-precision DC/RMS measurement with 2 channels and 12 measurement ranges.
- Isolated BNC connector with 1 MΩ input impedance and 30 pF input capacitance.
- Low-pass filter options: 5/50/500 Hz, 5 k/100 kHz.
- Measurement resolution of 1/100 of measurement range using 12-bit A/D conversion.
- Sampling rate of 1 MS/s for simultaneous sampling across 2 channels.
- Measurement accuracy of ±0.5 % of full scale with filter 5 Hz.
- RMS measurement with accuracy of ±1 % of full scale (DC, 30 Hz to 1 kHz).
- Compact design with dimensions 106 mm (4.17 in) W × 19.8 mm (0.78 in) H × 196.5 mm (7.74 in) D and weight 250 g (8.8 oz).
Rated 0 out of 5
(0)
- High-accuracy current measurement with up to 4 modules of 8971 compatible with Memory HiCorder models.
- 2 channels with current measurement using optional current sensor.
- Measurement range from 2 A to 2000 A f.s.
- 12-bit A/D measurement resolution.
- 1 MS/s sampling rate for simultaneous sampling across 2 channels.
- AC/DC/GND input coupling and low-pass filter options.
- Compact dimensions and lightweight design.
Rated 0 out of 5
(0)
- Measures frequency, rotation, power frequency, integration, pulse duty ratio, and pulse width
- 2 channels for voltage input based frequency measurement
- Isolated BNC connector with 1 MΩ input impedance and 30 pF input capacitance
- Max. rated voltage to earth: 300 V AC, DC
- Frequency mode: Range: DC to 100kHz, 1Hz/div to 5kHz/div
- Rotation mode: Range: 0 to 2 million rotations/minute, 100 (r/min)/div to 100k (r/min)/div
- Power frequency mode: Range: 50Hz, 60Hz, 400Hz
- Integration mode: Range: 2k counts/div to 1M counts/div
- Duty ratio mode: Range: 10Hz to 100kHz, 5%/div
- Pulse width mode: Range: 2μs to 2sec, 500μs/div to 100ms/dv
Rated 0 out of 5
(0)
- 2-channel high resolution unit for precise voltage measurement
- Isolated BNC input with 1 MΩ impedance and 30 pF capacitance
- Measurement range 5 mV to 20 V/div across 12 ranges
- 16-bit A/D conversion for 1/1600 measurement resolution
- 1 MS/s simultaneous sampling rate across both channels
- Frequency response DC to 100 kHz (-3 dB) with AC coupling 7 Hz to 5 MHz
- Includes anti-aliasing filter for FFT processing integrity
Rated 0 out of 5
(0)
- High 16-bit A/D resolution
- Isolated 2 channel input
- Max. rated voltage to ground: 300 V AC, DC
- Measurement functions: Number of channels: 2, for temperature measurement with thermocouple
- Input connectors: Thermocouple input: plug-in connector
- Temperature measurement range: 10 °C/div (-100 °C to 200 °C), 50 °C/div (-200 °C to 1000 °C), 100 °C/div (-200 °C to 2000 °C)
- Measurement resolution: 1/1000 of measurement range (using 16-bit A/D conversion and when installed in the 8847)
Rated 0 out of 5
(0)
- High 12-bit A/D resolution
- Isolated 2 channel input
- Max. rated voltage to ground: 300 V AC, DC
- Reliably capture instantaneous waveforms using high speed 20 MS/s sampling and A/D converter
- Measurement functions: 2 channels for voltage measurement
- Input connectors: Isolated BNC connector
- Measurement range: 5 mV to 20 V/div, 12 ranges
- Low-pass filter: 5/50/500 Hz, 5 k/50 k/500 kHz
- Measurement resolution: 1/100 of measurement range
- Highest sampling rate: 20 MS/s
Rated 0 out of 5
(0)
- The Hioki 3665-20 LAN CABLE HiTESTER is a handheld device for testing LAN cables.
- It checks wire map, measures cable length, and identifies twisted-pair cables.
- Useful for verifying connections after installing connectors on cables.
- Optional terminators facilitate easy identification of multiple cables.
- Convenient for testing cables in working networks in the event of faults caused by open- or short-circuited cable wiring.
- Measures twisted-pair cables with characteristic impedance of 100 Ω, shielded and unshielded, CAT 3, 4, 5, 5e, 6 and 6A.
Rated 0 out of 5
(0)
- Precision battery and capacitance testing up to 31000 digits
- Dual measurement ranges: 300 mΩ to 3 Ω resistance and 20 V DC voltage
- High accuracy ±0.5% rdg ±5 dgt with EX.FAST/FAST/Medium/Slow modes
- Comparator function with Hi/IN/Lo judgment and PASS/FAIL output
- Multiple sampling rates from 4 ms to 150 ms for flexible testing
- Robust design with 22 V DC measurement capability
- Rich interfaces including RS-232C, GP-IB, and External I/O
Rated 0 out of 5
(0)
- High speed measurement of 2ms
- Supports C measurements with voltage dependency characteristics through the use of constant voltage testing (CV)
- Model 3504-60 can detect contact failure on all 4 terminals for increased reliability
- BIN function on the 3504-60/-50 is ideal for sorting machines
- Model 3504-40 offers high speed and affordability, perfect for integrating into taping machines
- In all models, contact error is constantly monitored during measurement, contributing to increased yield
Rated 0 out of 5
(0)
- Compatible with the SPECpower® (*1) benchmarking for server power consumption
- DC measurement mode, AC, and AC+DC measurement
- Integration function for current and power
- ±0.1% high basic accuracy (*2) For complete details, please refer to the specifications)
- Extended period of guaranteed accuracy of 3 years
- Complete accuracy over a wide input range
Rated 0 out of 5
(0)
- Ideal for replacing portable instruments, ±0.1% basic accuracy
- Extended period of guaranteed accuracy of 3 years
- 50mA to 20A AC current range (300 V Max., Accuracy guaranteed up to 30 A)
- Print out with the 9442 and RS-232C interface
Bench Multimeters