Hioki

(0)
Call for price
  • 10 isolated analog channels using scanning input method (M3 mm dia. screw terminal block)
  • 4 pulse channels (All pulse inputs share common ground with the main unit)
  • ±100 mV to ±60 V measurement range with 6 ranges and Max. resolution 5µV
  • Temperature measurement from -200 ˚C to 1800 ˚C (depend on the sensor)
  • Internal storage capacity of 3.5 M-words
  • External storage options via CF card or USB memory stick
(0)
Call for price
  • 10 isolated analog channels using scanning input method (M3 mm dia. screw terminal block)
  • 4 pulse channels (All pulse inputs share common ground with the main unit)
  • ±100 mV to ±60 V measurement range with 6 ranges, Max. resolution 5µV
  • Temperature measurement from -200 ˚C to 1800 ˚C (depend on the sensor)
  • Internal storage capacity of 3.5 M-words
  • External storage options via CF card or USB memory stick
  • 4.3-inch WQVGA-TFT color LCD display for real-time data saving and numerical calculations
(0)
Call for price
  • Wireless logging station with up to 105 measurement channels.
  • Bluetooth wireless technology for control and data transfer.
  • Internal memory and SD/USB data storage options.
  • 5.7-inch TFT color display for real-time data visualization.
  • AC adapter, internal battery, and external power options.
  • Compact design with dimensions of 230mm x 125mm x 36mm.
  • Weight of 700g (excluding battery pack).
(0)
Call for price
  • Test LAN cables with precision and accuracy
  • Ensure reliable network connectivity
  • Compliant with industry standards
  • Easy to use and operate
  • High-quality construction
  • Long-lasting performance
  • Cost-effective solution
(0)
Call for price
  • Test voltage range: DC 250 V to 2.00 kV
  • Test voltage presets: 500 V, 1 kV, 1.5 kV
  • User-set test voltage: 250 V to 1 kV: in 10 V increments; 1 kV to 2 kV: in 25 V increments
  • Guaranteed accuracy range (1): 0.00 MΩ to 5.00 GΩ ±5% rdg ±5 dgt
  • Guaranteed accuracy range (2): 5.01 GΩ to 100 GΩ ±20% rdg
  • Rated current: [Test voltage] / [20 MΩ]
  • Open-circuit voltage: From 0% to 10% of test voltage
  • Short-circuit current: 2 mA or less
  • Possible number of measurements: 1000 times or more on one set of fully-charged batteries
(0)
Call for price
  • Test voltage range: DC 250 V to 2.00 kV
  • Test voltage presets: 500 V, 1 kV, 1.5 kV
  • User-set test voltage: 250 V to 1 kV: in 10 V increments; 1 kV to 2 kV: in 25 V increments
  • Guaranteed accuracy range (1): 0.00 MΩ to 5.00 GΩ ±5% rdg ±5 dgt
  • Guaranteed accuracy range (2): 5.01 GΩ to 100 GΩ ±20% rdg
  • Rated current: [Test voltage] / [20 MΩ]
  • Open-circuit voltage: From 0% to 10% of test voltage
  • Short-circuit current: 2 mA or less
  • Possible number of measurements: 1000 times or more on one set of fully-charged batteries
(0)
Call for price
  • Test voltage range: DC 250 V to 5.20 kV DC
  • User-set test voltage: 250 V to 1 kV: in 10 V increments; 1 kV to 5 kV: in 25 V increments
  • Test voltage preset: 250 V
  • Guaranteed accuracy range (1): 0.00 MΩ〜2.50 GΩ ±5% rdg ±5 dgt
  • Guaranteed accuracy range (2): 2.51 GΩ〜500 GΩ ±20% rdg
  • Rated current: 1 mA to 1.2 mA
  • Short-circuit current: 2 mA or less
  • Possible number of measurements: 200 times or more on one set of fully-charged batteries
(0)
Call for price
  • High-accuracy insulation testing with ±2% rdg. ±2 dgt. accuracy
  • Wide measuring range from 0.05 MΩ to 100 MΩ
  • Compact and lightweight design for easy handling
  • Long battery life with up to 20 hours of continuous use
  • Multiple safety features including live circuit indicator and automatic electric discharge
  • Easy-to-read display with semi-transmissive FSTN LCD and bar-graph indicator
  • Comprehensive accessories including test lead, neck strap, and instruction manual
(0)
Call for price
  • LCR mode for measuring inductance, capacitance, and resistance.
  • Analyzer mode for sweeps with measurement frequency and measurement level.
  • Continuous measurement mode for real-time measurement.
  • Measures Z, Y, θ, Rs (ESR), Rp, X, G, B, Cs, Cp, Ls, Lp, D (tanδ), Q parameters.
  • Measurable range: 100 mΩ to 5 kΩ.
  • Display range: Z: 0.00 m to 9.99999 GΩ / Rs, Rp, X: ± (0.00 m to 9.99999 GΩ) Ls, Lp: ± (0.00000 n to 9.99999 GH) / Q: ± (0.00 to 9999.99) θ: ± (0.000° to 180.000°), Cs, Cp: ± (0.00000 p to 9.99999 GF) D: ± (0.00000 to 9.99999), Y: (0.000 n to 9.99999 GS) G, B: ± (0.000 n to 9.99999 GS), Δ%: ± (0.000 % to 999.999 %).
  • Basic accuracy: Z: ±0.65 % rdg. θ: ±0.38°.
  • Measurement frequency: 1 MHz to 3 GHz (100 kHz setting resolution).
  • Measurement signal level: Power: -40.0 dBm to +1.0 dBm Voltage: 4 mV to 502 mVrms Current: 0.09 mA to 10.04 mArms.
  • Output impedance: 50 Ω (at 10 MHz).
  • Display: 8.4-inch color TFT with touch screen.
  • Measurement speeds: FAST: 0.5 ms (Analog measurement time, typical value).
  • Functions: Contact check, Comparator, BIN measurement (classification), Panel loading/saving, Memory function, Equivalent circuit analysis, Correlation compensation.
  • Interfaces: EXT I/O (Handler), USB communication, USB memory, LAN, RS-232C (optional), GP-IB (optional).
  • Power supply: 100 to 240 V AC, 50/60 Hz, 70 VA max..
  • Dimensions and mass: Main unit: 215 mm (8.46 in) W × 200 mm (7.87 in) H × 348 mm (13.70 in) D, 8.0 kg (282.2 oz) Test head: 90 mm (3.54 in) W × 64 mm (2.52 in) H × 24 mm (0.94 in) D, 300 g (10.58 oz).
  • Included accessories: Test head ×1, Connection cable ×1, Instruction manual ×1, Power cord ×1.
(0)
Call for price
  • Measurement modes: LCR mode, Analyzer mode (sweeps with measurement frequency and measurement level), Continuous measurement mode
  • Measurement parameters: Z, Y, θ, Rs (ESR), Rp, X, G, B, Cs, Cp, Ls, Lp, D (tanδ), Q
  • Measurable range: 100 mΩ to 5 kΩ
  • Display range: Z: 0.00 m to 9.99999 GΩ / Rs, Rp, X: ± (0.00 m to 9.99999 GΩ) Ls, Lp: ± (0.00000 n to 9.99999 GH) / Q: ± (0.00 to 9999.99) θ: ± (0.000° to 180.000°), Cs, Cp: ± (0.00000 p to 9.99999 GF) D: ± (0.00000 to 9.99999), Y: (0.000 n to 9.99999 GS) G, B: ± (0.000 n to 9.99999 GS), Δ%: ± (0.000 % to 999.999 %)
  • Basic accuracy: Z: ±0.65 % rdg. θ: ±0.38°
  • Measurement frequency: 1 MHz to 3 GHz (100 kHz setting resolution)
  • Measurement signal level: Power: -40.0 dBm to +1.0 dBm Voltage: 4 mV to 502 mVrms Current: 0.09 mA to 10.04 mArms
(0)
Call for price
  • LCR mode and Analyzer mode for comprehensive impedance measurement
  • Continuous measurement mode for real-time data analysis
  • Measurement parameters include Z, Y, θ, Rs, Rp, X, G, B, Cs, Cp, Ls, Lp, D, and Q
  • Measurable range from 100 mΩ to 5 kΩ
  • Display range for various parameters
  • Basic accuracy of ±0.65% rdg. for Z and ±0.38° for θ
  • Measurement frequency range of 1 MHz to 1.3 GHz
  • Measurement signal level range of -40.0 dBm to +1.0 dBm
(0)
Call for price
  • LCR mode and Analyzer mode for comprehensive impedance analysis
  • Continuous measurement mode for real-time monitoring
  • Measurement parameters include Z, Y, θ, Rs, Rp, X, G, B, Cs, Cp, Ls, Lp, D, and Q
  • Measurable range of 100 mΩ to 5 kΩ
  • Display range of 0.00 m to 9.99999 GΩ
  • Basic accuracy of ±0.65 % rdg. for Z and ±0.38° for θ
  • Measurement frequency of 1 MHz to 1.3 GHz
(0)
Call for price
  • LCR mode for precise measurements
  • Analyzer mode for sweeps with measurement frequency and level
  • Continuous measurement mode for real-time data
  • Measures Z, Y, θ, Rs, Rp, X, G, B, Cs, Cp, Ls, Lp, D, and Q
  • Measurable range: 100 mΩ to 5 kΩ
  • Display range: 0.00 m to 9.99999 GΩ
(0)
Call for price
  • LCR mode and Analyzer mode for impedance measurement
  • Continuous measurement mode for real-time monitoring
  • Measurable range of 100 mΩ to 5 kΩ
  • Display range of 0.00 m to 9.99999 GΩ
  • Basic accuracy of ±0.65 % rdg.
  • Measurement frequency of 1 MHz to 600 MHz
  • Measurement signal level of -40.0 dBm to +1.0 dBm
(0)
Call for price
  • LCR mode and Analyzer mode for precise measurements
  • Continuous measurement mode for real-time data
  • Measurable range of 100 mΩ to 5 kΩ
  • Display range of 0.00 m to 9.99999 GΩ
  • Basic accuracy of ±0.72 % rdg.
  • Measurement frequency of 100.00 kHz to 300.00 MHz
  • 8.4-inch color TFT with touch screen display
(0)
Call for price
  • LCR mode for measuring inductance, capacitance, and resistance.
  • Analyzer mode for sweeps with measurement frequency and level.
  • Continuous measurement mode for real-time measurement.
  • Measurable range of 100 mΩ to 5 kΩ.
  • Display range of 0.00 m to 9.99999 GΩ.
  • Measurement frequency of 100.00 kHz to 300.00 MHz.
  • Measurement signal level of -40.0 dBm to +7.0 dBm.
(0)
Call for price
  • Measurement modes: LCR mode, Analyzer mode (Sweeps with measurement frequency and measurement level), Continuous measurement mode
  • Measurement parameters: Z, Y, θ, Rs (ESR), Rp, X, G, B, Cs, Cp, Ls, Lp, D (tanδ), Q
  • Measurable range: 100 mΩ to 5 kΩ
  • Display range: Z: 0.00 m to 9.99999 GΩ / Rs, Rp, X: ± (0.00 m to 9.99999 GΩ) Ls, Lp: ± (0.00000 n to 9.99999 GH) / Q: ± (0.00 to 9999.99) θ: ± (0.000° to 180.000°), Cs, Cp: ± (0.00000 p to 9.99999 GF) D: ± (0.00000 to 9.99999), Y: (0.000 n to 9.99999 GS) G, B: ± (0.000 n to 9.99999 GS), Δ%: ± (0.000 % to 999.999 %)
  • Basic accuracy: Z: ±0.72 % rdg. θ: ±0.41°
  • Measurement frequency: 1.0000 MHz to 300.00 MHz (5 digits resolution)
  • Measurement signal level: Power: -40.0 dBm to +7.0 dBm Voltage: 4 mV to 1001 mVrms Current: 0.09 mA to 20.02 mArms
(0)
Call for price
  • LCR mode for precise measurements
  • Analyzer mode for sweeps and measurement frequency
  • Continuous measurement mode for real-time data
  • Measures Z, Y, θ, Rs, Rp, X, G, B, Cs, Cp, Ls, Lp, D, and Q
  • Measurable range: 100 mΩ to 5 kΩ
  • Display range: 0.00 m to 9.99999 GΩ
(0)
Call for price
  • LCR mode and Analyzer mode for comprehensive measurement
  • Continuous measurement mode for real-time data analysis
  • Temperature characteristics and equivalent circuit analysis for in-depth understanding
  • Measurement range from 100 mΩ to 100 MΩ with 10 ranges
  • Display range for various parameters including Z, Y, θ, Rs, Rp, Rdc, X, G, B, Cs, Cp, Ls, Lp, D, Q, T, σ, ε
  • Basic accuracy of ±0.05% rdg. for Z and ±0.03° for θ
  • Measurement frequency from 1 mHz to 200 kHz with 5 digits setting resolution
(0)
Call for price
  • LCR Meter for precise measurements
  • Measurement modes: LCR, Continuous testing
  • Measurement parameters: Z, Y, θ, X, G, B, Q, Rdc, Rs, Rp, Ls, Lp, Cs, Cp, D, σ, ε
  • Measurement range: 100 mΩ to 100 MΩ, 10 ranges
  • Display range: Z: 0.00 m to 9.99999 GΩ, Y: 0.000 n to 9.99999 GS, θ: ± (0.000° to 180.000°)
  • Basic accuracy: Z ±0.05% rdg., θ: ±0.03°
  • Measurement frequency: 4 Hz to 8 MHz
  • Measurement signal level: 4 Hz to 1.0000 MHz: 10 mV to 5 Vrms, 1.0001 MHz to 8 MHz: 10 mV to 1 Vrms
(0)
Call for price
  • LCR Meter with advanced measurement capabilities
  • Measurement modes: LCR, Transformer testing, and Continuous testing
  • Measurement parameters: Z, Y, θ, X, G, B, Q, Rdc, Rs, Rp, Ls, Lp, Cs, Cp, D, N, M, ΔL, T
  • Measurement range: 100 mΩ to 100 MΩ, 10 ranges
  • Displayable range: ± (0.00000 to 9.99999G)
  • Basic accuracy: Z : ±0.05% rdg., θ: ±0.03°
  • Measurement frequency: 1 mHz to 200 kHz
  • Measurement signal level: 5 mV to 5 Vrms, 1 mVrms steps
  • Output impedance: 100 Ω, Low impedance high repeatability mode: 25 Ω
  • Display: 5.7-inch touch-screen color TFT
  • Measurement time: 2 ms
  • Functions: DC bias measurement, DC resistance temperature compensation, Comparator, BIN measurement, Panel loading/saving, Memory function
  • Interfaces: EXT I/O (Handler), USB communication (high-speed), USB memory
  • Power supply: 100 to 240 V AC, 50/60 Hz, 50 VA max
  • Dimensions and mass: 330 mm W × 119 mm H × 168 mm D, 3.1 kg
(0)
Call for price
  • High-precision LCR measurement with 0.05% basic accuracy
  • Wide frequency range from 40 Hz to 200 kHz for diverse component testing
  • Comprehensive parameter set including Z, Y, Rs, Rp, Ls, Lp, Cs, Cp, D, Q and Rdc
  • Dual measurement modes: CV mode (voltage) and CC mode (current) with adjustable signal levels
  • Fast 2ms measurement time at 1 kHz for efficient production testing
  • Built-in comparator and BIN classification functions for quality control
  • Multiple interfaces including USB, LAN and EXT I/O for system integration
(0)
Call for price
  • Accurate earth resistance measurement with 10 ranges and 0.01 Ω resolution.
  • Multi-grounded system support for accurate measurements.
  • True RMS measurement for accurate AC current measurement.
  • 2000 data memory for storing measurement data.
  • Alarm function for resistance and current measurement.
  • Wireless communication for easy data transfer.
  • Dust-proof and waterproof design for rugged use.
(0)
Call for price
  • Accurate earth voltage measurements with ±2.3% rdg ±8 dgt accuracy.
  • Dustproof and waterproof design with IP65/IP67 rating.
  • Long battery life with 4 LR6 Alkaline batteries.
  • Wireless communication capabilities with Z3210 connection.
  • Live wire warning and zero-adjustment functions.
  • Continuous measurement mode for extended testing.
  • Comprehensive accessories including auxiliary earthing rod and carrying case.
  • Compact design with dimensions 185 mm (7.28 in)W × 111 mm (4.37 in)H × 44 mm (1.73 in)D.