-1%
Fluke 1550C FC 5 kV Digital Insulation Tester
Short Description:
The Fluke 1550C FC 5 kV Digital Insulation Tester is a sophisticated diagnostic tool designed for high-voltage insulation testing, crucial in maintaining and troubleshooting electrical equipment and systems.
Product purchase
AED 13,500 Original price was: AED 13,500.AED 13,400Current price is: AED 13,400. (excl.VAT)
18
People watching this product now!
Terms of sending goods ›
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
Fluke 1550C FC Insulation Tester
The Fluke 1550C FC 5 kV Digital Insulation Tester is a sophisticated diagnostic tool designed for high-voltage insulation testing, crucial in maintaining and troubleshooting electrical equipment and systems. This device is part of Fluke’s comprehensive range of test and measurement equipment, known for its reliability, accuracy, and durability.
Fluke 1550C FC Key Features:
- High Voltage Testing: Capable of testing up to 5 kV, the Fluke 1550C FC is ideal for high-voltage systems, providing clear insights into the insulation condition of electrical apparatus, helping to prevent equipment failure, and enhancing safety.
- Fluke Connect Compatibility: With Fluke Connect integration, this tester allows users to wirelessly transmit test results to their smartphone or tablet, facilitating easier monitoring, data logging, and sharing. This feature enhances the efficiency of maintenance routines and enables real-time collaboration among team members.
- Wide Measurement Range: The tester offers a broad range of insulation resistance measurements, up to 1 TΩ, making it versatile for a variety of high-voltage equipment, including switchgear, motors, and cables.
- Safety Features: Designed with safety in mind, the 1550C FC includes features such as an automatic discharge of capacitive voltage charges and a guard system to eliminate the effect of surface leakage current on high-resistance measurements.
- Durable and Portable: The robust design ensures reliability even in tough industrial environments, and its portability makes it convenient for field technicians to carry out comprehensive insulation testing on-site.
- Intuitive Interface and Display: The tester features an easy-to-use interface with a large, clear display, simplifying the setup and execution of insulation tests, and providing clear, easy-to-read results even in challenging conditions.
Fluke 1550C FC Applications:
The Fluke 1550 C FC is invaluable for preventative maintenance, commissioning, and troubleshooting of high-voltage electrical systems. It’s widely used in industries such as power generation, transmission and distribution, industrial electrical, and any sector where high-voltage equipment plays a critical role. It helps in assessing the quality of insulation in new installations, diagnosing problems in aging infrastructure, and conducting periodic maintenance checks to prevent unexpected downtime and accidents.
Fluke 1550C FC Specifications:
Electrical Specifications | ||
The tester’s accuracy is specified for one year after calibration at operating temperatures of 0°C to 35°C. For operating temperatures outside the range (-20°C to 0°C and 35°C to 50°C), add ± .25% per °C, except on the 20% bands add ± 1% per °C. | ||
Insulation Resistance Measurement | ||
Test voltage (DC) | ||
250 V | Range | < 250 kΩ, 250 kΩ to 5 GΩ 5 GΩ to 50 GΩ > 50 GΩ |
Accuracy (± reading) | Unspecified 5% 20% Unspecified |
|
500 V | Range | < 500 kΩ 500 kΩ to 10 GΩ 10 GΩ to 100 GΩ > 100 GΩ |
Accuracy (± reading) | Unspecified 5% 20% Unspecified |
|
1000 V | Range | < 1 MΩ 1 MΩ to 20 GΩ 20 GΩ to 200 GΩ > 200 GΩ |
Accuracy (± reading) | Unspecified 5% 20% Unspecified |
|
2500 V | Range | < 2.5 MΩ 2.5 MΩ to 50 GΩ 50 GΩ to 500 GΩ > 500 GΩ |
Accuracy (± reading) | Unspecified 5% 20% Unspecified |
|
5000 V | Range | < 5 MΩ 5 MΩ to 100 GΩ 100 GΩ to 1 TΩ > 1 TΩ |
Accuracy (± reading) | Unspecified 5% 20% Unspecified |
|
Bar graph range | 0 to 1 TΩ (1550C) – 0 to 2 TΩ (1555) | |
Insulation test voltage accuracy | -0%, +10% at 1 mA load current | |
Induced AC mains current rejection | 2 mA maximum | |
Charging rate for capacitive load | 5 seconds per μF | |
Discharge rate for capacitive load | 1.5 s/μF | |
Leakage current measurement | Range | 1 nA to 2 mA |
Accuracy | ± (5% + 2 nA) | |
Capacitance measurement | Range | 0.01 μF to 15.00 μF |
Accuracy | ± (15% rdg + 0.03 μF) | |
Timer | Range | 0 to 99 minutes |
Resolution setting | 1 minute | |
Resolution indication | 1 second | |
Live circuit warning | Warning range | 30 V to 660 V AC/DC, 50/60 Hz |
Voltage accuracy | ± (15% + 2 V) | |
Software specifications | FlukeView Formsâ„¢ basic software requires a PC running Windows XP, Windows Vista , Windows 7 or Windows 8. | |
General Specifications | ||
Display | 75 x 105 mm | |
Power | 12 V lead-acid rechargeable battery, Yuasa NP2.8-12 | |
Charger Input (AC) | 85 V to 250 V AC 50/60 Hz 20 VA | |
This Class II (double insulated) instrument is supplied with a Class 1 (grounded) power cord. The protective earth terminal (ground pin) is not connected internally. The extra pin is for added plug retention only. | ||
Dimensions | 269 x 277 x 160 mm (10.6 x 10.9 x 6.3 in) | |
Weight | 3.7 kg (8.2 lb) | |
Temperature (operating) | -20°C to 50°C (-4°F to 122°F) | |
Temperature (storage) | -20°C to 65°C (-4°F to 149°F) | |
Humidity | 80% to 31°C decreasing linearly to 50% at 50°C | |
Altitude | 2000 m | |
Enclosure sealing | IP40 | |
Input overload protection | 1000 V AC | |
Electromagnetic compatibility | EN 61326 | |
Safety compliance | IEC 61010-1: Overvoltage category II, Pollution Degree 2. IEC 61010-2-030: Measurement 600V CAT IV / 1000V CAT III IEC 61557-1, IEC 61557-2 |
Specifications
Electrical Specifications | ||
The tester’s accuracy is specified for one year after calibration at operating temperatures of 0°C to 35°C. For operating temperatures outside the range (-20°C to 0°C and 35°C to 50°C), add ± .25% per °C, except on the 20% bands add ± 1% per °C. | ||
Insulation Resistance Measurement | ||
Test voltage (DC) | ||
250 V | Range | < 250 kΩ, 250 kΩ to 5 GΩ 5 GΩ to 50 GΩ > 50 GΩ |
Accuracy (± reading) | Unspecified 5% 20% Unspecified |
|
500 V | Range | < 500 kΩ 500 kΩ to 10 GΩ 10 GΩ to 100 GΩ > 100 GΩ |
Accuracy (± reading) | Unspecified 5% 20% Unspecified |
|
1000 V | Range | < 1 MΩ 1 MΩ to 20 GΩ 20 GΩ to 200 GΩ > 200 GΩ |
Accuracy (± reading) | Unspecified 5% 20% Unspecified |
|
2500 V | Range | < 2.5 MΩ 2.5 MΩ to 50 GΩ 50 GΩ to 500 GΩ > 500 GΩ |
Accuracy (± reading) | Unspecified 5% 20% Unspecified |
|
5000 V | Range | < 5 MΩ 5 MΩ to 100 GΩ 100 GΩ to 1 TΩ > 1 TΩ |
Accuracy (± reading) | Unspecified 5% 20% Unspecified |
|
Bar graph range | 0 to 1 TΩ (1550C) – 0 to 2 TΩ (1555) | |
Insulation test voltage accuracy | -0%, +10% at 1 mA load current | |
Induced AC mains current rejection | 2 mA maximum | |
Charging rate for capacitive load | 5 seconds per μF | |
Discharge rate for capacitive load | 1.5 s/μF | |
Leakage current measurement | Range | 1 nA to 2 mA |
Accuracy | ± (5% + 2 nA) | |
Capacitance measurement | Range | 0.01 μF to 15.00 μF |
Accuracy | ± (15% rdg + 0.03 μF) | |
Timer | Range | 0 to 99 minutes |
Resolution setting | 1 minute | |
Resolution indication | 1 second | |
Live circuit warning | Warning range | 30 V to 660 V AC/DC, 50/60 Hz |
Voltage accuracy | ± (15% + 2 V) | |
Software specifications | FlukeView Formsâ„¢ basic software requires a PC running Windows XP, Windows Vista , Windows 7 or Windows 8. | |
General Specifications | ||
Display | 75 x 105 mm | |
Power | 12 V lead-acid rechargeable battery, Yuasa NP2.8-12 | |
Charger Input (AC) | 85 V to 250 V AC 50/60 Hz 20 VA | |
This Class II (double insulated) instrument is supplied with a Class 1 (grounded) power cord. The protective earth terminal (ground pin) is not connected internally. The extra pin is for added plug retention only. | ||
Dimensions | 269 x 277 x 160 mm (10.6 x 10.9 x 6.3 in) | |
Weight | 3.7 kg (8.2 lb) | |
Temperature (operating) | -20°C to 50°C (-4°F to 122°F) | |
Temperature (storage) | -20°C to 65°C (-4°F to 149°F) | |
Humidity | 80% to 31°C decreasing linearly to 50% at 50°C | |
Altitude | 2000 m | |
Enclosure sealing | IP40 | |
Input overload protection | 1000 V AC | |
Electromagnetic compatibility | EN 61326 | |
Safety compliance | IEC 61010-1: Overvoltage category II, Pollution Degree 2. IEC 61010-2-030: Measurement 600V CAT IV / 1000V CAT III IEC 61557-1, IEC 61557-2 |
5
Rated 5 out of 5
1 review
Rated 5 out of 5
1
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
1 review for Fluke 1550C FC 5 kV Digital Insulation Tester
Clear filters
Add a review Cancel reply
You must be logged in to post a review.
Related Products
Kyoritsu KEW 3551 Digital Insulation / Continuity Tester
Rated 5.00 out of 5
In stock
Kyoritsu Kew 3022A
Rated 5.00 out of 5
In stock
Kyoritsu 3161A Analogue Insulation Tester
Rated 0 out of 5
In stock
yaser –