Fluke 9170F Field Metrology Well –45°C to 140°C
Short Description:
The Fluke Calibration 9170-F Field Metrology Well Insert “F” is constructed from aluminum and features metric comparison holes, along with a 0.25-inch reference hole. With a temperature range from -45°C to 140°C, this insert ensures precise and reliable temperature calibration across a broad spectrum.
Product purchase
Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868
17
People watching this product now!
Terms of sending goods ›
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
Fluke Calibration 9170-F Field Metrology Well Insert “F”, Al, Metric Comparison Holes, w/ 0.25-inch Ref Hole –45°C to 140°C
The Fluke 9170F Field Metrology Well Insert “F” is constructed from aluminum and features metric comparison holes, along with a 0.25-inch reference hole. With a temperature range from -45°C to 140°C, this insert ensures precise and reliable temperature calibration across a broad spectrum.
Crafted with durable aluminum material, the fluke 9170-F insert provides consistent performance and reliability. Its metric comparison holes are designed to accommodate specific calibration requirements, while the 0.25-inch reference hole serves as a standard for calibration comparisons.
Whether utilized in laboratories, manufacturing facilities, or field environments, the Fluke 9170F Field Metrology Well Insert “F” is an essential tool for metrology professionals and technicians, enabling accurate temperature calibration with confidence.
fluke 9170 series
The Model 9170 stands out in the series by attaining the lowest temperatures, reaching as low as -45°C even under normal room conditions. With a stability rating of ±0.005°C across its entire temperature range (up to 140°C) and an immersion depth of 160 mm (6.3 in), it offers remarkable precision. Featuring axial uniformity of ±0.02°C and radial uniformity of ±0.01°C, this model boasts outstanding uncertainty budgets, making it an ideal choice for a wide range of pharmaceutical and other applications.
Fluke 9170 F Specifications:
Specifications | |||
Range (at 23°C ambient) | –45°C to 140°C (–49°F to 284°F) | ||
Display accuracy | ±0.1°C full range | ||
Stability | ±0.005°C full range | ||
Axial uniformity | ±0.1°C at –45°C ±0.04°C at –35°C ±0.02°C at 0°C ±0.07°C at 140°C |
||
Radial uniformity | ±0.01°C full range | ||
Loading effect (with a 6.35 mm reference probe and three 6.35 mm probes) | ±0.02°C at –45°C ±0.005°C at –35°C ±0.01°C at 140°C |
||
Hysteresis | 0.025°C | ||
Well depth | 160 mm (6.3 in) | ||
Resolution | 0.001°C | ||
Display | LCD, °C or °F, user-selectable | ||
Key pad | Ten key with decimal and ± button. Function keys, menu key, and °C / °F key. | ||
Cooling time | 44 min: 23°C to –45°C 19 min: 23°C to –30°C 19 min: 140°C to 23°C |
||
Heating time | 32 min: 23°C to 140°C 45 min: –45°C to 140°C |
||
Size (H x W x D) | 366 x 203 x 323 mm (14.4 x 8 x 12.7 in) | ||
Weight | 14.2 kg (31.5 lb) | ||
Power | 115 V AC (±10%), or 230 V AC (±10%), 50/60 Hz, 550 W |
||
Computer interface | RS-232 Interface with 9930 Interface-it control software included | ||
Traceable calibration (NIST) | Data at –45°C, 0°C, 50°C, 100°C, and 140°C | ||
Specifications | Built-in Reference Input | ||
Temperature range | –200°C to 962°C (–328°F to 1764°F) | ||
Resistance range | 0 Ω to 400 Ω, auto-ranging | ||
Characterizations | ITS-90 subranges 4, 6, 7, 8, 9, 10, and 11 Callendar-Van Dusen (CVD): R0, a, b, d | ||
Resistance accuracy | 0 Ω to 20 Ω: 0.0005 W 20 Ω to 400 Ω: 25 ppm |
||
Temperature accuracy (does not include probe uncertainty) |
10 Ω PRTs: ±0.013°C at 0°C ±0.014°C at 155°C ±0.019°C at 425°C ±0.028°C at 700°C |
25 Ω and 100 Ω PRTs: ±0.005°C at –100°C ±0.007°C at 0°C ±0.011°C at 155°C ±0.013°C at 225°C ±0.019°C at 425°C ±0.027°C at 661°C |
|
Resistance resolution | 0 Ω to 20 Ω: 0.0001 Ω 20 Ω to 400 Ω: 0.001 Ω |
||
Measurement period | 1 second | ||
Probe connection | 4-wire with shield, 5-pin DIN connector | ||
Calibration | NVLAP accredited (built-in reference input only), NIST-traceable calibration provided |
Rated 0 out of 5
0 reviews
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
Be the first to review “Fluke 9170F Field Metrology Well –45°C to 140°C” Cancel reply
You must be logged in to post a review.
Related Products
Fluke 1551a Stik Thermometer & Temperature Calibrator
Rated 5.00 out of 5
(1)
In stock
Call for Price
Reviews
Clear filtersThere are no reviews yet.