Fluke Calibration 9143: an epic Field Metrology Well
Short Description:
Fluke Calibration 9143 Field Metrology Well Key Features :
- Lightweight, portable, and fast
- Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
- True reference thermometry with accuracy to ±0.01 °C
- On-board automation and documentation
- Metrology performance in accuracy, stability, uniformity, and loading
Product purchase
Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868
20
People watching this product now!
Terms of sending goods ›
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
Fluke Calibration 9143 Field Metrology Well
Field probes are designed for the industrial process environment and quickly reach temperature. They weigh less than 8.2 kg and take up little space, making them easy to transport. Field environmental conditions are often unstable with large temperature swings.
Each field probe has built-in temperature gradient compensation (patent pending) that adjusts control characteristics to ensure stable performance in unstable environments. In fact, all specifications are guaranteed in the ambient range of 13 °C to 33 °C.
frequently asked questions
do fluke meters need to be calibrated?
As with any type of tool or piece of equipment, at some point, it will be necessary to calibrate a Fluke multimeter. Whether you use it as a hobby or in a highly regulated industry, to get consistent and accurate readings from the Fluke you need to calibrate it regularly
Is Fluke Calibration free?
To obtain a certificate of calibration contact the nearest Fluke Service Center to process an order to have your unit sent in for Calibration. A nominal fee is charged for calibration service.
Fluke Calibration 9143 Field Metrology Well Specifications:
- Temperature range at 23°C:33°C to 350°C (91°F to 662°F)
- Display accuracy:±0.2°C Full Range
- Stability:±0.02°C at 33°C,±0.02°C at 200°C,±0.03°C at 350°C
- Axial uniformity at 40 mm (1.6 in):±0.04°C at 33°C,±0.1°C at 200°C,±0.2°C at 350°C
- Radial uniformity:±0.01°C at 33°C,±0.015°C at 200°C,±0.02°C at 350°C
- Loading effect (with a 6.35 mm reference probe and three 6.35 mm probes):±0.015°C Full Range
- Hysteresis:0.03
- Operating conditions:0°C to 50°C, 0% to 90% RH (non-condensing)
- Environmental conditions (for all specifications except temperature range):13°C to 33°C
- Immersion (well) depth:150 mm (5.9 in)
- Insert OD:25.3 mm (1.00 in)
- Heating time:5 min: 33°C to 350°C
- Cooling time:32 min: 350°C to 33°C,14 min: 350°C to 100°C
- Resolution:0.01°
- Size (H x W x D):290 x 185 x 295 mm (11.4 x 7.3 x 11.6 in)
- Weight:7.3 kg (16 lb)
- Power requirements:100 V to 115 V (±10%), 50/60 Hz, 1400 W 230 V (±10%), 50/60 Hz, 1800 W
- Computer interface: RS-232 interface
5
Rated 5 out of 5
1 review
Rated 5 out of 5
1
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
1 review for Fluke Calibration 9143: an epic Field Metrology Well
Clear filters
Add a review Cancel reply
You must be logged in to post a review.
Kennedy –