Fluke CV201 ClirVu® 50 mm (2 in) Infrared Window

The Fluke CV201 ClirVu® 50 mm (2 in) Infrared Window offers a quick installation process that doesn’t require removing the panel door and instantly grounds to the metal enclosure.

SKU: 78554
Brand:Fluke

Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868

We are not Supporting COD Payments Terms Outside UAE

13 People watching this product now!

Fluke CV201 ClirVu® 50 mm (2 in) Infrared Window

The Fluke CV201 ClirVu® 50 mm (2 in) Infrared Window offers a quick installation process that doesn’t require removing the panel door and instantly grounds to the metal enclosure. It enhances safety by reducing the risk of arc-flash and electrocution, allowing for inspections with potentially less personal protective equipment and work permit requirements. This window withstands arc blasts with high test ratings, making it durable in harsh environments. It includes features such as a security key access, compatibility with all Fluke cameras, and is tested to perform in extreme temperatures.

Fluke CV201 Key Features

  • One technician
  • One hole with standard Greenlee® punch
  • Panel door does not need to be removed
  • Grounds instantly to metal enclosure with patent-pending AutoGround™ process
  • Maintains panel arc test ratings up to 63kA when properly installed

Fluke CV201 Specifications

General Specifications
Size 50 mm (2 in)
Voltage range Any
NEMA environment type Type 4/12 (indoor/outdoor)
AutoGround™ Yes
ClirVu® optic Yes
Operating temperature -40°C to +232°C (-40° F to +450°F) and +260°C (500°F) intermittent
Compatible with all Fluke cameras Yes
Jam nut locking system Yes
Cover and fastener permanently attached Yes
Single-hole install Yes
Hand turn and security key door latch options Yes
Visual inspection and fusion capable Yes
Short/Mid/Long-wave IR and UV capable Yes
Ratings and Testing
Arc-tested (IEEE C37.20.7) 63 kA for 30 cycles @ 60 Hz at KEMA
CSA C22.2 No. Yes
CSA type rating Type 4
IP rating IP67 at TUV
Lloyds register Up to 11 kV marine switchgear, indoor or outdoor (offshore only)
Vibration rating IEC60068-2-6 at TUV
Humidity rating IEC60068-2-3 at TUV
Install
Actual mounting hole diameter required 61.37 mm (2.416 in)
Greenlee® punch kit = punch/die 76BB = 441AV/442AV
Recommended max panel thickness 10 gage
Overall window height 112.9 mm (4.45 in)
Overall window width 83.0 mm (3.27 in)
Overall window thickness 16.2 mm (0.64 in)
Door latch Security Key
Optics
Optic insert diameter 50 mm (1.97 in)
Viewing aperture diameter 42.93 mm (1.690 in)
Viewing aperture area 1445 mm2 (2.24 in2)
Thickness 2 mm (0.08 in)
0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Fluke CV201 ClirVu® 50 mm (2 in) Infrared Window”

Datasheet