Fluke 1587 FC Insulation Multimeter

(13 customer reviews)

Short Description:

Fluke 1587 FC Insulation Multimeter helps you identify tough problems, fix, and wirelessly communicate your work quickly and easily – all at a safe distance.To get information about the Fluke 1587 price and other products fluke on our site contact us through MME.

Product purchase
SKU: 259 Categories: ,
Brand:Fluke

Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868

20 People watching this product now!
Terms of sending goods ›
  •  In-stock items are delivered within 2 business days.
  • We are not Supporting COD Payments Terms Outside UAE

Fluke 1587 FC Insulation Multimeter

Fluke Megger 1587

The Fluke 1587 FC is a versatile and advanced insulation multimeter, combining the functionality of an insulation tester with the versatility of a full-featured multimeter. This powerful tool is designed for troubleshooting and preventative maintenance in various industrial environments. Let’s dive into the key aspects of this exceptional device.

Manual- and auto-ranging digital insulation multimeter measures insulation resistance, current, voltage, capacitance, frequency, resistance, and temperature, and performs diode tests for testing line insulation on motors, generators, cables, and switchgear.

fluke 1587 review

True RMS meter provides accurate readings when measuring linear or nonlinear loads where the current or voltage has an undistorted or distorted waveform. Insulation test voltages of 50, 100, 250, 500, and 1000V and insulation measurement range of 0.01 megohms to 2 gigohms. The low-pass filter blocks unwanted voltages when measuring AC voltage and AC frequency to provide accurate measurements on inverters and variable-frequency motor drives.

Fluke 1587FC Insulation Multimeter Specifications:

Technical Specifications

Electrical Specifications
Measurement Range Accuracy
AC voltage measurement 600.0 mV Resolution: 0.1 mV
Accuracy 50 Hz to 60 Hz: ±(1% + 3)
Accuracy 60 Hz to 5000 Hz: ±(2% + 3)
6.000 V Resolution: 0.001 V
Accuracy 50 Hz to 60 Hz: ±(1% + 3)
Accuracy 60 Hz to 5000 Hz: ±(2% + 3)
60.00 V Resolution: 0.01 V
Accuracy 50 Hz to 60 Hz: ±(1% + 3)
Accuracy 60 Hz to 5000 Hz: ±(2% + 3)
600.0 V Resolution: 0.1 V
Accuracy 50 Hz to 60 Hz: ±(1% + 3)
Accuracy 60 Hz to 5000 Hz: ±(2% + 3)¹
1000 V Resolution: 1 V
Accuracy 50 Hz to 60 Hz: ±(2% + 3)
Accuracy 60 Hz to 5000 Hz: ±(2% + 3)¹
¹ 1 kHz bandwidth
Low-Pass Filter Voltage 600.0 mV Resolution: 0.1 mV
Accuracy 50 Hz to 60 Hz: ±(1% + 3)
Accuracy 60 Hz to 400 Hz: +(2% + 3), -(6% – 3)
6.000 V Resolution: 0.001 V
Accuracy 50 Hz to 60 Hz: ±(1% + 3)
Accuracy 60 Hz to 400 Hz: +(2% + 3), -(6% – 3)
60.00 V Resolution: 0.01 V
Accuracy 50 Hz to 60 Hz: ±(1% + 3)
Accuracy 60 Hz to 400 Hz: +(2% + 3), -(6% – 3)
600.0 V Resolution: 0.1 V
Accuracy 50 Hz to 60 Hz: ±(1% + 3)
Accuracy 60 Hz to 400 Hz: +(2% + 3), -(6% – 3)
1000 V Resolution: 1 V
Accuracy 50 Hz to 60 Hz: ±(2% + 3)
Accuracy 60 Hz to 400 Hz: +(2% + 3), -(6% – 3)
DC Voltage Measurement 6.000 V dc Resolution: 0.001 V
Accuracy: ±(0.09% + 2)
60.00 V dc Resolution: 0.01 V
Accuracy: ±(0.09% + 2)
600.0 V dc Resolution: 0.1 V
Accuracy: ±(0.09% + 2)
1000 V dc Resolution: 1 V
Accuracy: ±(0.09% + 2)
Input impedance: 10 MΩ (nominal), <100 pF
Normal mode rejection ratio: >60 dB @ 50 Hz or 60 Hz
Common mode rejection ratio: >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)
Accuracies apply to ± 100% of range
DC Millivolts Measurement 600.0 mVdc Resolution: 0.1 mV
Accuracy: ±(0.1% + 1)
DC and AC Current Measurement 400 mA (AC 45 Hz to 1000 Hz) Resolution: 0.1 mA
Accuracy: ±(1.5% + 2)¹
Burden voltage (Typical): 2 mV/mA
60 mA (AC 45 Hz to 1000 Hz) Resolution: 0.01 mA
Accuracy: ±(1.5% + 2)¹
Burden voltage (Typical): 2 mV/mA
400 mA (DC) Resolution: 0.1 mA
Accuracy: ±(0.2% + 2)
Burden voltage (Typical): 2 mV/mA
60 mA (DC) Resolution: 0.01 mA
Accuracy: ±(0.2% + 2)
Burden voltage (Typical): 2 mV/mA
Overload: 600 mA for 2 minutes maximum
Fuse protection for mA input: 0.44 mA, 1000 V, IR 10 kA
AC conversion: Inputs are ac-coupled and calibrated to the rms value of sine wave input
Conversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ≤1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3.
Ohms Measurement <

Range Resolution Accuracy
600.0 Ω 0.1 Ω ±(0.9% + 2)
6.000 kΩ 0.001 kΩ ±(0.9% + 2)
60.00 kΩ 0.01 kΩ ±(0.9% + 2)
600.0 kΩ 0.1 KΩ ±(0.9% + 2)
AC voltage range/resolution/accuracy

,

,

,

,

DC voltage range/resolution/Accuracy

,

,

,

AC current range/resolution/Accuracy

,

DC current range/resolution/Accuracy

400mA/0.1mA/±(0.2%rdg +2dgt)

,

60mA/0.01mA/±(0.2%rdg +2dgt)

Resistance Range/resolution/Accuracy

50.0MΩ/0.01MΩ/±(1.5%rdg +3dgt)

,

6.000MΩ/0.001MΩ/±(0.9%rdg +2dgt)

,

6.000Ω/0.001Ω/±(0.9%rdg +2dgt)

,

60.00Ω/0.01Ω/±(0.9%rdg +2dgt)

,

600.0Ω/0.1Ω/±(0.9%rdg +2dgt)

Capacitance Range/resolution/Accuracy

10.00 μF/0.01µF/±(1.2%rdg+2dgt)

,

100.0 μF/0.1µF/±(1.2%rdg+90dgt)

,

1000nF/1nF/±(1.2%rdg+2dgt)

,

999μF/1µF/±(1.2%rdg+90dgt)

Frequency range/resolution/Accuracy

9.999kHz/0.001kHz/±(0.1%rdg+1dgt)

,

99.99Hz/0.01Hz/±(0.1%rdg +1dgt)

,

99.99kHz/0.01kHz/±(0.1%rdg+1dgt)

,

999.9Hz/0.1Hz/±(0.1%rdg+1dgt)

Temperature range/resolution/ Accuracy

-40°C to 537°C/0.1°C/±(1%rdg+10dgt)

,

-40°C to 998°C/0.1°F/±(1%rdg+18dgt)

Dimensions

5.0 x 10.0 x 20.3 cm

Weight

550 g (1.2 lb)

Power

Four AA batteries (IEC LR6)

Operating temperature

-20 °C to 55 °C (-4 °F to 131 °F)

Storage temperature

-40 °C to 60 °C (-40 °F to 140 °F)

Operating altitude

2000 m

True RMS

√

Display Hold

√

Data Sheet

Data Sheet

Manual

Mme-pdfs-image

Specifications

Technical Specifications

Electrical Specifications
Measurement Range Accuracy
AC voltage measurement 600.0 mV Resolution: 0.1 mV
Accuracy 50 Hz to 60 Hz: ±(1% + 3)
Accuracy 60 Hz to 5000 Hz: ±(2% + 3)
6.000 V Resolution: 0.001 V
Accuracy 50 Hz to 60 Hz: ±(1% + 3)
Accuracy 60 Hz to 5000 Hz: ±(2% + 3)
60.00 V Resolution: 0.01 V
Accuracy 50 Hz to 60 Hz: ±(1% + 3)
Accuracy 60 Hz to 5000 Hz: ±(2% + 3)
600.0 V Resolution: 0.1 V
Accuracy 50 Hz to 60 Hz: ±(1% + 3)
Accuracy 60 Hz to 5000 Hz: ±(2% + 3)¹
1000 V Resolution: 1 V
Accuracy 50 Hz to 60 Hz: ±(2% + 3)
Accuracy 60 Hz to 5000 Hz: ±(2% + 3)¹
¹ 1 kHz bandwidth
Low-Pass Filter Voltage 600.0 mV Resolution: 0.1 mV
Accuracy 50 Hz to 60 Hz: ±(1% + 3)
Accuracy 60 Hz to 400 Hz: +(2% + 3), -(6% – 3)
6.000 V Resolution: 0.001 V
Accuracy 50 Hz to 60 Hz: ±(1% + 3)
Accuracy 60 Hz to 400 Hz: +(2% + 3), -(6% – 3)
60.00 V Resolution: 0.01 V
Accuracy 50 Hz to 60 Hz: ±(1% + 3)
Accuracy 60 Hz to 400 Hz: +(2% + 3), -(6% – 3)
600.0 V Resolution: 0.1 V
Accuracy 50 Hz to 60 Hz: ±(1% + 3)
Accuracy 60 Hz to 400 Hz: +(2% + 3), -(6% – 3)
1000 V Resolution: 1 V
Accuracy 50 Hz to 60 Hz: ±(2% + 3)
Accuracy 60 Hz to 400 Hz: +(2% + 3), -(6% – 3)
DC Voltage Measurement 6.000 V dc Resolution: 0.001 V
Accuracy: ±(0.09% + 2)
60.00 V dc Resolution: 0.01 V
Accuracy: ±(0.09% + 2)
600.0 V dc Resolution: 0.1 V
Accuracy: ±(0.09% + 2)
1000 V dc Resolution: 1 V
Accuracy: ±(0.09% + 2)
Input impedance: 10 MΩ (nominal), <100 pF
Normal mode rejection ratio: >60 dB @ 50 Hz or 60 Hz
Common mode rejection ratio: >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)
Accuracies apply to ± 100% of range
DC Millivolts Measurement 600.0 mVdc Resolution: 0.1 mV
Accuracy: ±(0.1% + 1)
DC and AC Current Measurement 400 mA (AC 45 Hz to 1000 Hz) Resolution: 0.1 mA
Accuracy: ±(1.5% + 2)¹
Burden voltage (Typical): 2 mV/mA
60 mA (AC 45 Hz to 1000 Hz) Resolution: 0.01 mA
Accuracy: ±(1.5% + 2)¹
Burden voltage (Typical): 2 mV/mA
400 mA (DC) Resolution: 0.1 mA
Accuracy: ±(0.2% + 2)
Burden voltage (Typical): 2 mV/mA
60 mA (DC) Resolution: 0.01 mA
Accuracy: ±(0.2% + 2)
Burden voltage (Typical): 2 mV/mA
Overload: 600 mA for 2 minutes maximum
Fuse protection for mA input: 0.44 mA, 1000 V, IR 10 kA
AC conversion: Inputs are ac-coupled and calibrated to the rms value of sine wave input
Conversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ≤1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3.
Ohms Measurement <

Range Resolution Accuracy
600.0 Ω 0.1 Ω ±(0.9% + 2)
6.000 kΩ 0.001 kΩ ±(0.9% + 2)
60.00 kΩ 0.01 kΩ ±(0.9% + 2)
600.0 kΩ 0.1 KΩ ±(0.9% + 2)
4.3
13 reviews
6
3
3
0
0

13 reviews for Fluke 1587 FC Insulation Multimeter

Clear filters
  1. Christopher

    Great meter. Fluke connect is handy as well.

  2. melanie

    Value for money
    Durability
    Delivery speed

    Excellent

  3. mick

    Value for money
    Durability
    Delivery speed

    high quality insulation multimeter

  4. Ahmed Al Mansoori (verified owner)

    outstanding performance

  5. Zarooni (verified owner)

    highly versatile tool

  6. Mohammed (verified owner)

    accurate and consistent results

  7. Ayesha Al Suwaidi (verified owner)

    great connectivity features

  8. Rashid (verified owner)

    rugged and durable

  9. Layla Shamsi (verified owner)

    excellent display

  10. Omar (verified owner)

    time-saving capabilities

  11. Sara (verified owner)

    worth the investment

  12. Khalid Nuaimi (verified owner)

    comprehensive safety features

  13. Zayed Mazrouei (verified owner)

    long battery life

Add a review