-9%
Fluke 1663 Multifunction Testers
AED 7,700 Original price was: AED 7,700.AED 7,500Current price is: AED 7,500. (excl.VAT)
Fluke 120B Series Industrial handheld Oscilloscopes
Call for Price
Fluke 1662 Multifunction Tester
The Fluke 1662 Multifunction Testers installation tester gives you Fluke reliability and all the basic testing power you need for day-in, day-out installation testing. It tests all local regulations and is easy and intuitive to use. To get information about the Fluke 1662 price be in touch with our experts.
Rated 5.00 out of 5 based on 1 customer rating
(1 customer review)
SKU:
3107
Brand:Fluke
AED 6,500 Original price was: AED 6,500.AED 5,900Current price is: AED 5,900. (excl.VAT)
3 in stock
We are not Supporting COD Payments Terms Outside UAE
13
People watching this product now!
Fluke 1662 Multifunction Installation Tester
Fluke 1662 Multifunction Testers are versatile electrical testing instruments used in household and commercial settings. These testers give precise and consistent readings, guaranteeing that electrical systems are safe and meet regulatory requirements.
Advantages of Fluke 1662
One of the key benefits of the Fluke 1662 Multifunction Testers is their exceptional precision. These testers deliver accurate measurements of voltage, current, and resistance, ensuring that electrical systems function correctly. Additionally, the devices are user-friendly, featuring an intuitive interface and straightforward controls, enabling electricians and technicians to perform tests more quickly and efficiently.
Another advantage of Fluke 1662 Multifunction Testers is their long life. These devices are built to endure tough environments including accidental drops and collisions. They are also designed for safety, with features including overvoltage protection and a built-in continuity test. Furthermore, the device comes with a three-year warranty, giving users peace of mind.
The Fluke 1662 installation tester offers the trusted reliability of Fluke along with all the essential testing capabilities needed for routine installation testing. It meets all local standards and is designed for ease of use. Additional features, like the On/Off switchable auto-start for RCD and loop tests, as well as a self-test function, help save time and increase your confidence in the results.
The fluke 1662 tester user manual explains how to use the instrument safely and efficiently. The Fluke 1662 insulation resistance test is an essential tool for everyone working in the electrical industry, thanks to its extensive capabilities and user-friendly interface. Whether you need to test circuits, measure voltage, or look for flaws, this tester will always deliver accurate and dependable results. for the fluke multifunction tester price visit our website.
Key Features
- RCD switching time and tripping level are measured (ramp test).
- Trip time and current are measured for RCD types A and AC in a single test.
- RCD variable current is measured.
- An automatic RCD test sequence is provided.
- Includes Z-max memory for loop tests to facilitate determining the highest loop test value.
- Provides a one-of-a-kind zero adapter for quick, dependable, and accurate test lead and power cord adjustment.
- A phase sequence indicator is included.
- It includes a durable carrying case, comfortable carrying and waist straps, as well as a remote control probe and lead.
5
Rated 5 out of 5
1 review
Rated 5 out of 5
1
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
1 review for Fluke 1662 Multifunction Tester
Clear filters
Add a review Cancel reply
You must be logged in to post a review.
specifications
AC voltage measurement | ||
Range | 500 V | |
Resolution | 0.1 V | |
Accuracy 45 Hz – 66 Hz | 0.8% + 3 | |
Input impedance | 360 kΩ | |
Overload protection | 660 V rms | |
Continuity testing (RLO) | ||
Range (autoranging) | 20 Ω / 200 Ω / 2000 Ω | |
Resolution | 0.01 Ω / 0.1 Ω / 1 Ω | |
Open Circuit Voltage | >4 V | |
Insulation resistance measurement (RISO) | ||
Accuracy of test voltage (at rated test current) | +10%, -0% | |
Test voltage | 100 V 250 V 500 V 1000 V |
|
Insulation resistance range | 20 MΩ / 50 MΩ 20 MΩ / 100 MΩ 20 MΩ / 200 MΩ 20 MΩ / 200 MΩ / 500 MΩ 20 MΩ / 200 MΩ / 1000 MΩ |
|
Resolution | 0.01 MΩ / 0.1 MΩ 0.01 MΩ / 0.1 MΩ 0.01 MΩ / 0.1 MΩ 0.01 MΩ / 0.1 MΩ / 1 MΩ 0.01 MΩ / 0.1 MΩ / 1 MΩ |
|
Test current | 1 mA @ 50 kΩ 1 mA @ 100 kΩ 1 mA @ 250 kΩ 1 mA @ 500 kΩ 1 mA @ 1 MΩ |
|
Loop and line impedance (ZI) | ||
Range | 10 Ω / 0.001 Ω / High current mΩ mode | |
Resolution | 0.01 Ω / 0.1 Ω / 1 Ω | |
Prospective earth fault current, PSC test | ||
Range | 1000 A / 10 kA (50 kA) | |
Resolution | 1 A / 0.1 kA | |
Computation | Prospective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively. | |
RCD testing, RCD types tested | ||
RCD Type | A4, AC¹, G², S³ | |
Notes | ¹Responds to AC ²General, no delay ³Time delay 4Responds to pulsed signal 5Responds to smooth DC signal |
|
Tripping speed test (ΔT) | ||
Current settings¹ | 10-30-100-300-500-1000 mA – VAR 10-30-100 mA |
|
Multiplier | x ½, x 1 x 5 |
|
Measurement range | RCD Type G | 310 ms 50 ms |
RCD Type S | 510 ms 160 ms |
|
Notes | ¹1000 mA type AC only 700 mA maximum type A in VAR mode VAR mode not available for type B. |
|
RCD/FI-Tripping Current Measurement/Ramp Test (IΔN) | ||
Current range | 30% to 110% of RCD rated current¹ | |
Step size | 10% of IΔN² | |
Dwell time | Type G | 300 ms/step |
Type S | 500 ms/step | |
Measurement accuracy | ±5% | |
Specified trip current ranges (EN 61008-1) | 50% to 100% for Type AC 35% to 140% for Type A (>10 mA) 35% to 200% for Type A (≤10 mA) 50% to 200% for Type B ²5% for Type B |
|
Notes | ¹30% to 150% for Type A IΔN > 10 mA 30% to 210% for Type A IΔN = 10 mA 20% to 210% for Type B |
|
Phase Sequence Indication | ||
General Specifications | ||
Size (L x W x H) | 10 x 25 x 12.5 cm | |
Weight (incl. batteries) | 1.3 (kg) | |
Battery size, quantity | Type AA, 6 ea. | |
Sealing | IP-40 | |
Safety | Complies with EN/IEC 61010-1 and EN/IEC 61010-2-034 | |
Overvoltage | CAT III / 500V; CAT IV 300V | |
Performance | EN61557-1 to EN61557-7 and EN61557-10 |