Fluke 1777 Basic Power Quality Analyzer (No probes)
Short Description:
The Fluke 1777 Basic Power Quality Analyzer, without probes, is an essential tool designed for analyzing and monitoring power quality in electrical systems. While it does not include probes, it is compatible with a variety of probes and accessories, enabling users to conduct a wide range of power quality measurements.
Product purchase
Call for Best Price In UAE 00971(04) 447 6031 00971(04) 344 9868
11
People watching this product now!
Terms of sending goods ›
- In-stock items are delivered within 2 business days.
- We are not Supporting COD Payments Terms Outside UAE
Fluke 1777/Basic Power Quality Analyzer (No probes)
The Fluke 1777 Basic Power Quality Analyzer, without probes, is an essential tool designed for analyzing and monitoring power quality in electrical systems. While it does not include probes, it is compatible with a variety of probes and accessories, enabling users to conduct a wide range of power quality measurements. Here are some key features of the Fluke 1777 Basic Power Quality Analyzer:
- Power Quality Analysis: The Fluke 1777 is equipped to measure various parameters crucial to power quality assessment, such as voltage, current, frequency, power factor, harmonics, and flicker. This comprehensive analysis offers insights into the electrical power’s quality within a system.
- High Precision Measurements: With its high precision measurements, the Fluke 1777 ensures accurate data acquisition, facilitating precise identification and diagnosis of power quality issues.
- Waveform Capture: The analyzer possesses the capability to capture and record voltage and current waveforms. This functionality allows users to scrutinize transient events, sags, swells, interruptions, and other irregularities in the electrical system.
- Harmonics Analysis: The Fluke 1777 can detect and analyze harmonics present within the electrical system. This capability aids in identifying harmonic distortion and understanding its potential impact on equipment and overall system performance.
- Data Logging: Built-in data logging capabilities enable users to record power quality parameters over time. This feature is invaluable for conducting long-term monitoring and trend analysis.
- Real-time Monitoring: Users can monitor real-time measurements and waveforms directly on the analyzer’s display, facilitating rapid assessment of power quality conditions.
- Reporting and Analysis Software: The Fluke 1777 is accompanied by software tailored for analyzing recorded data, generating comprehensive reports, and conducting in-depth analysis of power quality issues.
- Remote Monitoring: Some models may offer remote monitoring capabilities, allowing users to access measurement data and analysis remotely via network connections, enhancing flexibility and convenience.
- Rugged Design: Engineered to endure harsh industrial environments, the Fluke 1777 features a rugged design that ensures durability and reliability in demanding conditions.
Overall, the Fluke 1777 Basic Power Quality Analyzer serves as an indispensable tool for power quality analysis, offering advanced features and capabilities when used in conjunction with compatible probes and accessories.
Fluke 1777 Basic Features
- Automatically measure power and power quality parameters
- At-a-glance power quality health for faster troubleshooting
- Easily view V/A/Hz, power, dips, swells, and harmonics data
- Capture high-speed transients up to 8 kV
- Power directly from measurement circuit without a line cord
Fluke 1777 Basic Specifications:
Power quality measurements | ||
---|---|---|
Measured parameter | See operator manual | |
Harmonics | h0 … h50 % fund and RMS for voltage, current and power Phase angles for voltage and current up to h11 |
|
Interharmonics | ih0… ih50 % fund and RMS for voltage and current |
|
Supraharmonics | 2–9 kHz with 200 Hz bins 9–30 khz with 2 kHz bins RMS for voltage and current |
|
Harmonics measurement method | Grouped, sub-grouped and single harmonic bins according to IEC 61000-4-7. Method selected automatically based on configured PQ standard or user configurable. |
|
Total harmonic distortion | Calculated on up to 50 harmonics (depends on selected PQ standard) | |
Mains signaling | 2 frequencies in the range from 110 Hz to 3000 Hz | |
Events | Voltage | Dip, swell, interruption, rapid voltage change, mains signaling, waveshape deviation, transients |
Current | Inrush current | |
Triggered recordings | Half cycle RMS of voltage and current for 10 s Waveform of voltage and current for 10/12 cycles Mains signaling: 200 ms RMS of mains signaling voltage up to 120 s Transients: Waveform of voltage (Fluke 1777: 1 MS/s or 20 MS/s, 500,000 pts, Fluke 1775: 1 MS/s, 25,000 pts) |
Electrical measurement accuracy
Parameter | Range | Resolution | Intrinsic Accuracy at Reference Conditions % of Reading + % of Full Scale |
|
---|---|---|---|---|
Voltage | 1000 V | 0.1 V | 0.1 % of nominal voltage in accordance with IEC 61000-4-30 Class A1,2 ±(0.04 % + 0.004 %)3 |
|
Voltage dips and swells | – | 0.1 V | 0.2 % of Vnom1,2 | |
Voltage transients | ±8 kVpk | – | ±5 % +0.25 %) | |
Voltage harmonics/interharmonics | 100 % | 0.1 % / 0.1 mV | ≥1 % Vnom1:  ±2.5 % of rdg. <1 % Vnom1:  ±0.025 Vnom |
|
THD on voltage | 100 % | 0.1 % / 0.1 V | ±(2.5 % + 0.5 %) | |
Voltage distortions 2-9 kHz | Max 100 V | 0.1 mV | ±(2.5 % + 0.1 V) | |
Voltage distortions 9-30 kHz | Max 100 V | 0.1 mV | ±(2.5 % + 0.1 V) | |
Current (Rogowski clamp mode) |
With iFlex 1500 A, i17XX-FLEX1500 24 |
150 A 1500 A |
0.01 % 0.1 A |
±(1 % + 0.02 %) |
With iFlex 3000 A, i17XX-FLEX3000 24 |
300 A 3000 A |
0.01 A 0.1 A |
±(1 % + 0.03 %) | |
With iFlex 6000 A, i17XX-FLEX6000 36 |
600 A 6000 A |
0.1 A 1 A |
±(1.5 % + 0.03 %) | |
With AC clamp 40 A, i40s-EL |
4 A 40 A |
0.001 A 0.01 A |
±(0.7 % + 0.02 %) | |
With AC clamp 400 A, i400s-EL |
40 A 400 A |
0.01 A 0.1 A |
±(2 % + 0.2 %) ±(0.7 % + 0.1 %) |
|
With AC/DC clamp 2000 A, 80i-2010s-EL |
200 A 2000 A |
0.01 A 0.1 A |
±(0.8 % + 0.2 %) | |
Current min/max | 100 % | defined by accessory | x2 of intrinsic accuracy | |
Current harmonics/interharmonics | 100 % | 0.1 % / 0.01 A | ≥3 % Inom:  ±2.5 % of rdg.4 <3 % Inom:  ±0.15 % of Inom |
|
THD on current | 100 % | 0.1 % | ±(2.5 % + 0.5 %) | |
Frequency | 42.5 Hz … 69 Hz | 0.001 Hz | ±0.01 Hz | |
Voltage unbalance | 100 % | 0.1 % | ±0.15 % | |
Current unbalance | 100 % | 0.1 % | ±0.15 % | |
Flicker Pinst, Pst, Plt | 0 to 20 | 0.01 | 5 % | |
Mains signaling voltage | Up to 3 kHz 0-15 % of Vnom |
0.1 V / 0.1 % | 1-3 % Vnom: ±0.15 % of Vnom 3-15 % Vnom: ±5 % of rdg. |
|
AUX input | ±10 V | 0.1 mV | ±(0.2 % + 0.05 %) | |
1 Nominal voltage in the range of 100 V to 690 V. Also known as Udin. 2 0 °C to 45 °C: Intrinsic Accuracy x2. Outside of 0 °C to 45 °C: Intrinsic Accuracy x3 3 Only for calibration laboratories 4 With iFlex 1500A, I17XX-FLEX1500 24 |
Rated 0 out of 5
0 reviews
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
Be the first to review “Fluke 1777 Basic Power Quality Analyzer (No probes)” Cancel reply
You must be logged in to post a review.
Related Products
Kyoritsu KEW 6315-05 Power Quality Analyzer
Rated 5.00 out of 5
(1)
In stock
Kyoritsu 6315-01 Power Quality Analyzer Kit with Bluetooth
Rated 5.00 out of 5
(2)
In stock
Kyoritsu 6315-00 Power Quality Analyzer with Bluetooth
Rated 5.00 out of 5
(2)
In stock
Fluke 434 II and 435 II Power Quality and Energy Analyzers
Rated 5.00 out of 5
(1)
In stock
Call for Price
Reviews
Clear filtersThere are no reviews yet.