Fluke i3000s Flex-24 AC Current Clamp, 610 mm (24 in.)
The Fluke i3000s Flex-24 AC Current Clamp is a versatile and robust device designed for use in a variety of industrial and power environments. This clamp utilizes the Rogowski principle and is capable of measuring currents up to 3000 A.
Call for Price
We are not Supporting COD Payments Terms Outside UAE
Fluke i 3000s Flex-24 AC Current Clamp
The Fluke i3000s Flex-24 AC Current Clamp is a versatile and robust device designed for use in a variety of industrial and power environments. This clamp utilizes the Rogowski principle and is capable of measuring currents up to 3000 A. It’s particularly noted for its flexibility and ease of use in tight spaces, making it an ideal choice for measuring distorted current waveforms and harmonics.
Fluke i3000s flex 24 Features
- Three ranges: 30 A, 300 A & 3000 A, 1, 10 or 100 mV/A output
- Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
- Maximum conductor diameter 178 mm (7 in.)
- CAT III 600 V safety rating
Fluke i3000s Specifications:
Electrical Specifications | |
Current ranges | 30 A |
300 A | |
3000 A | |
AC rms | |
Output sensitivity (AC-coupled) | 100 mV |
10 mV | |
1 mV per A | |
Load impedance | 100 kΩ minimum |
Accuracy | at +25°C: ±1% of range (45 Hz to 65 Hz) |
Linearity | 10% to 100% of range: ±0.2% of reading |
Noise | 8 mV AC rms (30 A) |
2 mV AC rms (300 A, 3000 A) | |
Frequency range | 10 Hz to 50 kHz (-3 dB) |
Phase error | < ±1° (45 Hz to 65 Hz) |
±10° (at 20 kHz) | |
Position Sensitivity (with cable > 25 mm from the coupling) | ![]() Position sensitivity: From 1% up to 3% of range with cable, depending on distance from the center (see figure left). Measurements closer than 25 mm from the coupling are typically greater than 3% of range. External wire influence: 1% (-40 db) of external current >200 mm from head. |
External field | with cable > 200 mm from the head: ±1% of range |
Power supply | 2 x AA/MN 1500/LR6 Alkaline, 400 hours, low battery indicator |
Temperature coefficient | ±0.08% of reading per °C |
Working voltage | see Safety standards section: 600 V AC rms or DC |
General Specifications | |
Head circumference | 610 mm (24 in) |
Head cable diameter | 14.3 mm (0.56 in) |
Head bend radius | 38.1 mm (1.5 in) |
Cable length (head to electronics) | 2 m (6.56 ft) |
Output connection | 0.5 m cable terminated with safety BNC connector. Supplied with 4mm safety plug adapter |
Operating temperature range | -20°C to +90°C (-4°F to 190°F) (head) |
-20°C to +85°C (-4°F to 185°F) (electronics) | |
Storage temperature range | -40°C to +105°C (-40°F to 221°F) (head) |
-20°C to +85°C (-4°F to 185°F) (electronics) | |
Operating humidity | 15% to 85% (non-condensing) |
Weight | 180 g (0.396 lb) (head) |
190 g (0.419 lb) (electronics) | |
Safety standards | BS EN 61010-1: 2001 |
BS EN 61010-2-032: 2002 | |
BS EN 61010-031: 2002 | |
600 Vrms, Category III, Pollution Degree 2 | |
Use of the probe on uninsulated conductors is limited to 600 V AC rms or DC and frequencies below 1 kHz | |
EMC standards | EN 61326: 1998 +A1, A2, & A3 |
Head cable length (double insulated) | 610 mm or 914 mm, depending on model |
You must be logged in to post a review.
Brand
Fluke
![Fluke logo brand](https://mme-ae.com/wp-content/themes/woodmart/images/lazy.png)
Datasheet
Related Products
Fluke 28 ii Ex Intrinsically Safe Digital Multimeter
In stock
Fluke 378 FC Voltage AC/DC Clamp Meter
In stock
Fluke 381 True RMS Clamp Meter
In stock
FLUKE 376 FC Clamp Meter
In stock
Fluke 179 True RMS Digital Multimeter
In stock
FLUKE 902 FC True-RMS HVAC Clamp Meter
In stock
Fluke 117 Electricians Multimeter
In stock
Reviews