  • Rated measurement current: 5 A AC
  • Max. measurement current: Continuous 50 A (45 to 66 Hz)
  • Output rate: 10 mV AC/ A
  • Amplitude accuracy: ±0.3 % rdg. ±0.02 % f.s.
  • Phase accuracy: ±2° (45 Hz to 5 kHz)
  • Measurable conductor diameter: φ 15 mm (0.59 in) or less
  • Operating temperature and humidity: 0°C to 50°C (32°F to 122°F), 80% RH or less (no condensation)
(0)
Call for price
  • Measures leak current in AC 10 A (50/60 Hz)
  • Max. allowable input: 10 A of continuous input
  • Rated output current: AC 100 mV/A
  • Amplitude accuracy: ±1.0 % rdg. ±0.005 % f.s.
  • Phase accuracy: ±5 ° (at 50 Hz or 60 Hz)
  • Measurable conductor: Insulated conductor
  • Core diameter: φ 30 mm (1.18 in)
(0)
Call for price
  • 100:1 Division ratio with ±3% accuracy at 100 VDC
  • 100:1 Division ratio with +3%, -7% accuracy at 1000 VDC
  • 5 kV peak input voltage for reliable measurements
  • 100 MΩ input impedance for minimal signal loss
  • DC to 200 MHz frequency range for accurate measurements
  • 7 pF or less input capacitance for reduced noise
  • 1.5 m cable length for convenient use
(0)
Call for price
  • Rated measurement current: 500 A AC
  • Max. measurement current: Continuous 550 A (45 to 66 Hz)
  • Output rate: 1 mV AC/ A
  • Amplitude accuracy: ±0.3% rdg. ±0.01% f.s.
  • Phase accuracy: ±0.5° (45 Hz to 5 kHz)
  • Measurable conductor diameter: φ 46 mm (1.81 in) or less
  • Operating temperature and humidity: 0°C to 50°C (32°F to 122°F), 80% RH or less (no condensation)
(0)
Call for price
  • Rated measurement current: 100 A AC
  • Max. measurement current: Continuous 130 A (45 to 66 Hz)
  • Output rate: 1 mV AC/ A
  • Amplitude accuracy: ±0.3 % rdg. ±0.02 % f.s.
  • Phase accuracy: ±1° (45 Hz to 5 kHz)
  • Measurable conductor diameter: φ 15 mm (0.59 in) or less
  • Operating temperature and humidity: 0°C to 50°C (32°F to 122°F), 80% RH or less (no condensation)
(0)
Call for price
  • Rated primary current: AC 10 A (for leak current measurement, 50/60 Hz)
  • Max. allowable input: Max. 30 A of continuous input
  • Rated output current: AC 100 mV/A
  • Amplitude accuracy: ±1.0 % rdg. ±0.05 % f.s.
  • Phase accuracy: ±3 ° (at 50 Hz or 60 Hz)
  • Frequency characteristics: 40 Hz to 5 kHz: ± 3% (Add to amplitude accuracy)
  • Measurable conductor: Insulated conductor
  • Core diameter: φ 40 mm (1.57 in)
(0)
Call for price
  • Advanced waveform analysis with 256 channels analog and 128 channels logic
  • Waveform display, X-Y display, and Digital value display
  • Parameter calculation and search functions
  • Supports various file formats including .MEM, .REC, and .RMS
  • Print functions including image file output and hard copy
  • Compatible with Windows 11, 10/8/7
(0)
Call for price
  • LAN Communicator for Hioki devices
  • 9333 model
  • Downloadable license cards available
  • Easy communication with Hioki devices
  • Compact design for easy use
  • Reliable performance in various environments
  • Wide range of applications in electrical measurement
(0)
Call for price
  • Detect voltage signals or relay contact signals with the Hioki 9327 Logic Probe.
  • 4-channel input with common ground between unit and channels.
  • Switchable input for digital or contact input.
  • High input resistance for accurate signal detection.
  • Compact design with carrying case and accessories.
  • Reliable measurement for electrical signal detection.
  • Perfect for electrical engineers and technicians.
(0)
Call for price
  • DC mode: Waveform monitor output, DC to 10 MHz ±3 dB
  • AC mode: Detection of power line surge noise, 1 kHz to 10 MHz ±3 dB (Low frequency cut-off frequency 1 kHz ± 300 Hz)
  • RMS mode: Rectified RMS output of DC and AC voltages, DC, 40 Hz to 100 kHz
  • Response speed: 200 ms or less (400 V AC)
  • Max. allowable input: 2000 V DC, 1000 V AC
  • Max. rated voltage to earth: When using the Grabber Clip L9243: 1000 V AC/DC (CAT II), When using alligator clip: 1000 V AC/DC (CAT II), 600 V AC/DC (CAT III)
  • Output: Voltage division ratio: 1/1000, BNC terminal (DC/AC/RMS 3-mode selectable output)
  • DC amplitude accuracy: ±1 % f.s. (1000 V DC or less), ±3 % f.s. (2000 V DC or less) (f.s.=2000 V DC)
  • RMS amplitude accuracy: ±1 % f.s. (DC, 40 Hz to 1 kHz), ±4 % f.s. (1 kHz to 100 kHz) (f.s.=1000 VAC)
  • Input resistance, capacity: H-L: 9 MΩ, approx 10 pF (C at 100 kHz), H-case, L-case: 4.5 MΩ, approx 20 pF (C at 100 kHz)
  • Power supply: +5 V to +12 V, less than 300 mA (DC jack OD 5.5 mm [0.22 in.], ID 2.1 mm [0.08 in.])
  • Dimensions and mass: 70 mm (2.76 in.)W × 150 mm (5.91 in.)H × 25 mm (0.98 in.)D, 285 g (10.1 oz.), Cord length: Input 46 cm (1.51 ft.), Output 1.3 m (4.27 ft.)
  • Included accessories: Alligator clips ×1 (red/black set), Grabber Clip L9243 ×1 (red/black set), Carrying case C0203 ×1, Instruction manual ×1
(0)
Call for price
  • Rated current: 20 A to 1000 A AC, 6 ranges
  • Accuracy: ±3 % rdg. ±0.2 % f.s. (45 to 66 Hz)
  • Frequency characteristics: Add to amplitude accuracy for frequencies from 40 to 1 kHz: ± 1 % rdg.
  • Output rate: 0.2 V AC f.s. (f.s. = setting rage)
  • Max. allowable input: 1000 A rms continuous (all ranges)
  • Max. rated voltage to earth: 600 Vrms (50/60 Hz, CAT III)
  • Core diameter: φ55 mm (2.17 in), or 20 mm (0.79 in) × 80 mm (3.15 in) busbar
  • Dimensions and mass: 100 mm (3.94 in)W × 224 mm (8.82 in)H × 35 mm (1.38 in)D, 600 g (21.2 oz)
(0)
Call for price
  • Rated current: 10 A to 500 A AC, 6 ranges
  • Accuracy: ±1.5% rdg. ±0.1% f.s. (45 to 66 Hz)
  • Frequency characteristics: Add to amplitude accuracy : ± 1% rdg. Add to phase accuracy : ± 2.5° for frequencies from 40 Hz to 3 kHz
  • Output rate: 0.2 V AC f.s. (f.s. = setting rage)
  • Max. allowable input: 150 A rms continuous (10/20/50 A ranges) 400 A rms continuous (100/200 A ranges) 650 A rms continuous (500 A range)
  • Max. rated voltage to earth: 600 V rms (50 Hz/60 Hz, CAT III)
  • Core diameter: φ46 mm (1.81 in)
  • Dimensions and mass: 78 mm (3.07 in) W × 188 mm (7.40 in) H × 35 mm (1.38 in) D, 420 g (14.8 oz)
  • Cord length: 3 m (9.84 ft)
(0)
Call for price
  • Rated current: 10 A to 500 A AC, 6 ranges
  • Accuracy: ±2 % rdg. ±1 % f.s. (45 to 66 Hz)
  • Frequency characteristics: Add to amplitude accuracy for frequencies from 40 to 1 kHz
  • Output rate: 0.2 V AC f.s.
  • Max. allowable input: 150 A rms continuous
  • Max. rated voltage to earth: 600 Vrms (50/60 Hz, CAT III)
  • Core diameter: φ46 mm (1.81 in)
  • Dimensions and mass: 78 mm (3.07 in)W × 188 mm (7.40 in)H × 35 mm (1.38 in)D, 420 g (14.8 oz)
(0)
Call for price
  • High-precision DC/RMS measurement with 2 channels and 12 measurement ranges.
  • Isolated BNC connector with 1 MΩ input impedance and 30 pF input capacitance.
  • Low-pass filter options: 5/50/500 Hz, 5 k/100 kHz.
  • Measurement resolution of 1/100 of measurement range using 12-bit A/D conversion.
  • Sampling rate of 1 MS/s for simultaneous sampling across 2 channels.
  • Measurement accuracy of ±0.5 % of full scale with filter 5 Hz.
  • RMS measurement with accuracy of ±1 % of full scale (DC, 30 Hz to 1 kHz).
  • Compact design with dimensions 106 mm (4.17 in) W × 19.8 mm (0.78 in) H × 196.5 mm (7.74 in) D and weight 250 g (8.8 oz).
(0)
Call for price
  • High-accuracy current measurement with up to 4 modules of 8971 compatible with Memory HiCorder models.
  • 2 channels with current measurement using optional current sensor.
  • Measurement range from 2 A to 2000 A f.s.
  • 12-bit A/D measurement resolution.
  • 1 MS/s sampling rate for simultaneous sampling across 2 channels.
  • AC/DC/GND input coupling and low-pass filter options.
  • Compact dimensions and lightweight design.
(0)
Call for price
  • Measures frequency, rotation, power frequency, integration, pulse duty ratio, and pulse width
  • 2 channels for voltage input based frequency measurement
  • Isolated BNC connector with 1 MΩ input impedance and 30 pF input capacitance
  • Max. rated voltage to earth: 300 V AC, DC
  • Frequency mode: Range: DC to 100kHz, 1Hz/div to 5kHz/div
  • Rotation mode: Range: 0 to 2 million rotations/minute, 100 (r/min)/div to 100k (r/min)/div
  • Power frequency mode: Range: 50Hz, 60Hz, 400Hz
  • Integration mode: Range: 2k counts/div to 1M counts/div
  • Duty ratio mode: Range: 10Hz to 100kHz, 5%/div
  • Pulse width mode: Range: 2μs to 2sec, 500μs/div to 100ms/dv
(0)
Call for price
  • 2-channel high resolution unit for precise voltage measurement
  • Isolated BNC input with 1 MΩ impedance and 30 pF capacitance
  • Measurement range 5 mV to 20 V/div across 12 ranges
  • 16-bit A/D conversion for 1/1600 measurement resolution
  • 1 MS/s simultaneous sampling rate across both channels
  • Frequency response DC to 100 kHz (-3 dB) with AC coupling 7 Hz to 5 MHz
  • Includes anti-aliasing filter for FFT processing integrity
(0)
Call for price
  • High 16-bit A/D resolution
  • Isolated 2 channel input
  • Max. rated voltage to ground: 300 V AC, DC
  • Measurement functions: Number of channels: 2, for temperature measurement with thermocouple
  • Input connectors: Thermocouple input: plug-in connector
  • Temperature measurement range: 10 °C/div (-100 °C to 200 °C), 50 °C/div (-200 °C to 1000 °C), 100 °C/div (-200 °C to 2000 °C)
  • Measurement resolution: 1/1000 of measurement range (using 16-bit A/D conversion and when installed in the 8847)
(0)
Call for price
  • High 12-bit A/D resolution
  • Isolated 2 channel input
  • Max. rated voltage to ground: 300 V AC, DC
  • Reliably capture instantaneous waveforms using high speed 20 MS/s sampling and A/D converter
  • Measurement functions: 2 channels for voltage measurement
  • Input connectors: Isolated BNC connector
  • Measurement range: 5 mV to 20 V/div, 12 ranges
  • Low-pass filter: 5/50/500 Hz, 5 k/50 k/500 kHz
  • Measurement resolution: 1/100 of measurement range
  • Highest sampling rate: 20 MS/s
(0)
Call for price
  • The Hioki 3665-20 LAN CABLE HiTESTER is a handheld device for testing LAN cables.
  • It checks wire map, measures cable length, and identifies twisted-pair cables.
  • Useful for verifying connections after installing connectors on cables.
  • Optional terminators facilitate easy identification of multiple cables.
  • Convenient for testing cables in working networks in the event of faults caused by open- or short-circuited cable wiring.
  • Measures twisted-pair cables with characteristic impedance of 100 Ω, shielded and unshielded, CAT 3, 4, 5, 5e, 6 and 6A.
(0)
Call for price
  • Precision battery and capacitance testing up to 31000 digits
  • Dual measurement ranges: 300 mΩ to 3 Ω resistance and 20 V DC voltage
  • High accuracy ±0.5% rdg ±5 dgt with EX.FAST/FAST/Medium/Slow modes
  • Comparator function with Hi/IN/Lo judgment and PASS/FAIL output
  • Multiple sampling rates from 4 ms to 150 ms for flexible testing
  • Robust design with 22 V DC measurement capability
  • Rich interfaces including RS-232C, GP-IB, and External I/O
(0)
Call for price
  • High speed measurement of 2ms
  • Supports C measurements with voltage dependency characteristics through the use of constant voltage testing (CV)
  • Model 3504-60 can detect contact failure on all 4 terminals for increased reliability
  • BIN function on the 3504-60/-50 is ideal for sorting machines
  • Model 3504-40 offers high speed and affordability, perfect for integrating into taping machines
  • In all models, contact error is constantly monitored during measurement, contributing to increased yield
(0)
Call for price
  • Compatible with the SPECpower® (*1) benchmarking for server power consumption
  • DC measurement mode, AC, and AC+DC measurement
  • Integration function for current and power
  • ±0.1% high basic accuracy (*2) For complete details, please refer to the specifications)
  • Extended period of guaranteed accuracy of 3 years
  • Complete accuracy over a wide input range
(0)
Call for price
  • Ideal for replacing portable instruments, ±0.1% basic accuracy
  • Extended period of guaranteed accuracy of 3 years
  • 50mA to 20A AC current range (300 V Max., Accuracy guaranteed up to 30 A)