Rated 0 out of 5
(0)
- Rated current: 1000 A AC/DC
- Max. allowable input: Up to ±1800 Apeak (design value) allowed at 40°C or less for 20 ms or less
- Frequency bandwidth: DC to 1.5 MHz (CT6876A), DC to 1.2 MHz (CT6876A-1)
- Basic accuracy: ±0.04 % rdg. ±0.008 % f.s.
- Output voltage rate: 2 mV / A rated
- Max. rated voltage to earth: 1000 V AC/DC (50/60 Hz, CAT III)
- Core diameter: φ 36 mm (1.42 in)
- Operating temperature, humidity: -40°C to +85°C (-40°F to 185°F), 80% RH or less (with no condensation)
- Power supply: Power supplied via the Power Analyzer PW8001, PW6001, PW3390, or Sensor Unit CT9555, CT9556, CT9557, or 3ch Current Unit U8977
Rated 0 out of 5
(0)
- Rated current: 500 A AC/DC
- Max. allowable input: Up to ±1500 Apeak (design value) allowed at 40°C or less for 20 ms or less
- Frequency bandwidth: DC to 2 MHz (CT6875A), DC to 1.5 MHz (CT6875A-1)
- Basic accuracy: ±0.04 % rdg. ±0.008 % f.s.
- Output voltage rate: 4 mV / A rated
- Max. rated voltage to earth: 1000 V AC/DC (50/60 Hz, CAT III)
- Core diameter: φ 36 mm (1.42 in)
- Operating temperature, humidity: -40°C to +85°C (-40°F to 185°F), 80% RH or less (with no condensation)
Rated 0 out of 5
(0)
- High accuracy AC/DC current measurement
- Rated current: 200 A AC/DC
- Max. allowable input: ±420 A peak
- Frequency bandwidth: DC to 10 MHz
- Basic accuracy: ±0.03% rdg. ±0.002% f.s.
- Operating temperature: -40°C to +85°C
- Power supply: PW8001, PW6001, PW3390, or Sensor Unit CT9555
Rated 0 out of 5
(0)
- Rated current: 50 A AC/DC
- Max. allowable input: ±150 A peak (design value) allowed at 40°C or less for 20 ms or less
- Frequency bandwidth: DC to 10 MHz (amplitude), DC to 1 MHz (phase)
- Basic accuracy: DC (±0.03% rdg. ±0.002% f.s., no phase specification)
- Output voltage rate: 40 mV/A rated
- Max. rated voltage to earth: 1000 V CAT III
- Core diameter: φ 24 mm (0.94 in)
Rated 0 out of 5
(0)
- Rated current: 1000 A AC/DC
- Frequency bandwidth: DC to 100 kHz
- Diameter of measurable conductors: Max. φ 50 mm (1.97 in.)
- Max. allowable input: ±1900 A peak (Within 20 ms in an environment of 40°C/104°F or less)
- Output voltage: 2 mV/A
- Output resistance: 50 Ω ± 10 Ω
- Accuracy (amplitude): ±(% of reading + % of full scale)
- Linearity: ±20 ppm
- Typical Common-Mode Voltage Rejection Ratio (CMRR): DC to 1 kHz:150 dB or greater
Rated 0 out of 5
(0)
- Rated current: 500 A AC/DC
- Frequency bandwidth: DC to 500 kHz
- Diameter of measurable conductors: Max. φ 20 mm (0.79 in.)
- Max. allowable input: ±800 A peak (Within 20 ms in an environment of 40°C/104°F or less)
- Output voltage: 4 mV/A
- Output resistance: 50 Ω ± 10 Ω
- Accuracy (amplitude): ±(% of reading + % of full scale)
- Linearity: ±20 ppm
- Typical Common-Mode Voltage Rejection Ratio (CMRR): DC to 1 kHz:150 dB or greater
Rated 0 out of 5
(0)
- Measures AC/DC currents up to 200 A
- Frequency bandwidth: DC to 700 kHz
- Diameter of measurable conductors: Max. φ 20 mm (0.79 in.)
- Output voltage: 10 mV/A
- Accuracy: ±0.2% + 0.02% DC
- Automatic phase correction
- Compact dimensions: 153 mm W × 67 mm H × 25 mm D
Rated 0 out of 5
(0)
- Frequency bandwidth: DC to 120 MHz (-3 dB)
- Rise time: 2.9 ns or shorter
- Delay time (Typical): 30 A range: 12 ns, 5 A range: 12 ns, 0.5 A range: 13 ns
- Noise level: 75 μA rms max (at 0.5 A range, using 20 MHz band measuring instrument)
- Max. rated current: 30 A range: 30 A rms, 5 A range: 5 A rms, 0.5 A range: 0.5 A rms
- Max. allowable peak current: 30 A range: ±50 A peak, 5 A range: ± 7.5 A peak, 0.5 A range: ± 0.75 A peak
- Amplitude accuracy: 30 A range: ±3.0% rdg. ±1 mV, 5 A range: ±3.0% rdg. ±1 mV, 0.5 A range: ±3.0% rdg. ±10 mV
- Output rate: 30 A range: 0.1 V/A, 5 A range: 1 V/A, 0.5 A range: 10 V/A
Rated 0 out of 5
(0)
- Measures DC to 50 MHz (-3 dB)
- Rise time: 7.0 ns or shorter
- Delay time (Typical): 30 A range: 12 ns, 5 A range: 12 ns, 0.5 A range: 13 ns
- Noise level: 75 μA rms max
- Max. rated current: 30 A range: 30 A rms, 5 A range: 5 A rms, 0.5 A range: 0.5 A rms
- Max. allowable peak current: 30 A range: ±50 A peak, 5 A range: ± 7.5 A peak, 0.5 A range: ± 0.75 A peak
- Amplitude accuracy: 30 A range: ±3.0% rdg. ±1 mV, 5 A range: ±3.0% rdg. ±1 mV, 0.5 A range: ±3.0% rdg. ±10 mV
- Output rate: 30 A range: 0.1 V/A, 5 A range: 1 V/A, 0.5 A range: 10 V/A
- Measurable conductors: φ 5 mm (0.20 in), Insulated conductor
Rated 0 out of 5
(0)
- AC/DC Clamp Meter with True RMS measurement
- DC Current range: 1000 A, AC Current range: 1000 A
- DC Voltage range: 600.0 mV to 1000 V, AC Voltage range: 6.000 V to 1000 V
- Resistance range: 600.0 Ω to 6.000 MΩ, Electrostatic capacity range: 1.000 μF to 1000 μF
- Frequency range: 9.999 Hz to 999.9 Hz, Temperature range: -40.0°C to 400.0°C
- Continuity check, Diode check, and more
Rated 0 out of 5
(0)
- AC/DC Clamp Meter with high accuracy and wide measurement range
- True RMS measurement for AC current and voltage
- DC current and voltage polarity detection function
- Continuity check and diode check
- Automatic AC/DC detection and low-pass filter function
- Display value hold and auto hold
- Backlight and auto power save
- Buzzer sound and zero-adjustment
Rated 0 out of 5
(0)
- High-accuracy measurements with ±1.3% rdg. ±0.3 A basic accuracy
- True RMS for accurate AC current measurements
- Wide measurement range from 6.000 V to 1000 V and 600.0 Ω to 6.000 MΩ
- Compact and lightweight design with IP20 and IP54 ratings
- Long battery life with up to 40 hours of continuous use
- Includes test lead, carrying case, and instruction manual
Rated 0 out of 5
(0)
- True RMS AC/DC measurement
- 600.0 A/2000 A current range
- 6.000 V to 1000 V voltage range
- Resistance, capacitance, and frequency measurement
- Temperature measurement and harmonic analysis
- IP54 dustproof and waterproof design
- Long battery life and included accessories
Rated 0 out of 5
(0)
- True RMS measurement for accurate AC current and voltage readings.
- High accuracy of ±1.3% rdg. ±0.3 A for DC current and ±0.9% rdg. ±0.003 V for AC voltage.
- Wide measurement range for DC current (600.0 A/2000 A), AC current (600.0 A/2000 A), DC voltage (600.0 mV to 1000 V), and AC voltage (6.000 V to 1000 V).
- Multi-functionality with features such as DC power, continuity check, diode check, and automatic AC/DC detection.
- Long battery life of up to 40 hours with two LR03 Alkaline batteries.
- Dustproof and waterproof design with IP54 rating.
Rated 0 out of 5
(0)
- True RMS measurement for accurate AC current and voltage readings.
- DC current and voltage measurement up to 2000 A and 1000 V.
- Resistance, capacitance, and frequency measurement capabilities.
- Temperature measurement with optional temperature probe.
- Harmonic analysis with optional Z3210 module.
- IP54 rating for dust and water resistance.
- Long battery life with up to 40 hours of continuous use.
Rated 0 out of 5
(0)
- True RMS AC/DC measurement
- High accuracy with ±1.3% rdg. ±0.08 A (20 A range)
- Wide measurement range for DC current, AC current, DC voltage, AC voltage, resistance, capacitance, and frequency
- Temperature measurement with ±0.5% rdg. ±3.0 ˚C accuracy
- Harmonic levels up to 30th order with Z3210 installed
- Long battery life with up to 40 hours of continuous use
- Dustproof and waterproof design with IP20 and IP54 ratings
Rated 0 out of 5
(0)
- True RMS AC Clamp Meter for accurate measurements
- 60.00 A to 2000 A current range, 3 ranges
- 600.0 mV to 1700 V DC voltage range, 5 ranges
- 6.000 V to 1000 V AC voltage range, 4 ranges
- 600.0 Ω to 600.0 kΩ resistance range, 4 ranges
- 1.000 μF to 1000 μF electrostatic capacity range, 4 ranges
- 9.999 Hz to 999.9 Hz frequency range, 3 ranges
Rated 0 out of 5
(0)
- Accurate and reliable battery testing
- Wide range of battery testing capabilities
- Easy to use and operate
- High-quality construction and durability
- Compliance with international safety standards
- Long-lasting battery life
- Low maintenance requirements
Rated 0 out of 5
(0)
- Insulation resistance test
- Break Down Detect function (BDD)
- Contact check function
- Output specifications: 25 V to 500 V, 50 µA to 50 mA
- Resistance value display range: 0.050 MΩ to 9999 MΩ
- Memory functions: Panel save function, Measured value memory function
- Judgment functions: Test modes, Comparator function
Rated 0 out of 5
(0)
- Measures resistance and voltage with high accuracy and speed.
- Wide measurement ranges for various applications.
- Compact and lightweight design for easy handling.
- Multiple interfaces for easy data transfer.
- Long-lasting power supply for continuous use.
- Accurate and reliable results for confident decision-making.
- Comprehensive accessories for easy setup and use.
Rated 0 out of 5
(0)
- Resistance measurement ranges: 3 mΩ, 30 mΩ, 300 mΩ, 3 Ω, 30 Ω, 300 Ω, 3 kΩ
- Basic accuracy: ±0.5% rdg ±10 dgt (3 mΩ range), ±0.5% rdg ±5 dgt (30 mΩ range or more)
- Measurement frequency: 1 kHz ±0.2 Hz
- Voltage measurement ranges: 6 V, 60 V, 100 V
- Basic accuracy: ±0.01% rdg. ±3 dgt
- Response time: 10 ms
- Sampling period: 4 ms to 253 ms
Rated 0 out of 5
(0)
- Measures resistance and voltage with high accuracy and speed.
- Wide measurement range for various applications.
- Compact and lightweight design for easy handling.
- RS-232C and GP-IB interfaces for easy data transfer.
- External I/O and analog output for expanded functionality.
- Meets international safety standards for reliable operation.
- Comes with instruction manual and power cord for easy setup and use.
Rated 0 out of 5
(0)
- Rated measurement current: 100 A AC
- Max. measurement current: Continuous 130 A (45 to 66 Hz)
- Output rate: 1 mV AC/ A
- Amplitude accuracy: ±0.3 % rdg. ±0.02 % f.s. (*1)
- Phase accuracy: ±1° (45 Hz to 5 kHz)
- Amplitude frequency characteristics: Within ±1% at 40 Hz – 5 kHz (deviation from amplitude accuracy)
- Max. rated voltage to earth: 300 V AC rms or less (Insulated conductor)
- Measurable conductor diameter: φ 15 mm (0.59 in) or less
Rated 0 out of 5
(0)
- Rated measurement current: 50 A AC
- Max. measurement current: Continuous 60 A (45 to 66 Hz)
- Output rate: 10 mV AC/ A
- Amplitude accuracy: ±0.3 % rdg. ±0.02 % f.s. (*1)
- Phase accuracy: ±2° (45 Hz to 5 kHz)
- Amplitude frequency characteristics: Within ±1% at 40 Hz – 5 kHz (deviation from amplitude accuracy)
- Max. rated voltage to earth: 300 V AC rms or less (Insulated conductor)
- Measurable conductor diameter: φ 15 mm (0.59 in) or less
Bench Multimeters