Megger (437 products)
The Megger IDAX300 uses Dielectric Frequency Response (DFR/FDS) to measure moisture content, tan delta and oil conductivity in power transformer, bushing and CT insulation.
The Megger HPG-H series are compact, modular AC and DC high-voltage test systems with maintenance-free cast-resin transformers, delivering up to 110 kV DC / 78 kV AC (HPG110-H) for cable, switchgear and HV-component testing.
The Megger HPG-D series are compact, modular AC and DC high-voltage test systems with maintenance-free cast-resin transformers, delivering up to 160 kV DC / 58 kV AC (HPG80-D) for testing cables, switchgear and HV components.
The Megger HPG35, HPG50, HPG58 and HPG78 are portable AC high-voltage test sets for AC withstand (hipot) testing of switchgear, instrument transformers and MV components, with maximum AC outputs from 35 to 78 kVrms and a separate control unit for safe-distance operation.
The Megger STX40 is a portable cable fault location system for LV and MV cables. It combines DC testing to 40 kV, surge (thumping) to 32 kV with 2000 J, and TDR, arc reflection, ICE and decay prelocation, all controlled from a sunlight-readable 10.1-inch touchscreen with a single rotary knob.
The Megger HPA series is a portable, two-piece 50 Hz high-voltage test system delivering up to 100–120 kV AC (HPA 100/110/120) or 130 kV DC (HPA 130), rated 5 kVA continuous with low partial-discharge noise for testing switchgear, cables, bus-bars and transformers.
The Megger DELTA4000 Series is a 12 kV variable-frequency tan delta and power factor test system for diagnosing the insulation of transformers, bushings, cables, circuit breakers and rotating machines, with patented Individual Temperature Correction and strong on-site noise suppression.
The Megger CDAX 605 is a high-precision capacitance and dissipation-factor (tan-delta) measurement instrument for transformers, bushings and insulators, achieving 0.02% capacitance and 0.001% dissipation-factor accuracy over a 5-400 Hz frequency range.
The Megger SPG5-1000 is a compact 5 kV surge generator and cable fault locating system for low-voltage distribution networks. It combines DC testing, fault conditioning/burning, ICEplus surge prelocation and acoustic pinpointing — delivering surge energy up to 1000 J to find faults even in branched, multi-T-joint cables.
The Megger SmartFuse 2 (SmartFuse 250) is an intelligent electronic fuse system that replaces conventional LV fuses to monitor low-voltage networks in real time, locate cable faults without disconnecting consumers and automatically restore supply, with current up to 250 A.
The Megger Smart Thump ST25-30 is a higher-power portable/vehicle-mount cable fault location system for MV cables (11–35 kV). It combines TDR, arc reflection, ICE, DC proof testing to 30 kV and surge (thumping) up to 25 kV with 1600 J, plus automatic fault interpretation on a sunlight-readable display.
The Megger Smart Thump ST16-20 is a portable, integrated cable fault location system for medium-voltage distribution cables (11–35 kV). It combines TDR, arc reflection, ICE, DC proof testing and surge (thumping) up to 16 kV with automatic fault interpretation on a sunlight-readable touchscreen.
The Megger SFX32 is a portable cable test and fault location system for LV and MV cables. It combines TDR, arc reflection (ARM), ICE, decay, surge (1750 J) and DC test/burning up to 32 kV with a touchscreen Teleflex SX reflectometer to prelocate, condition and pinpoint cable faults.
The Megger Fault Sniffer 2 pinpoints low-voltage underground cable faults by detecting combustion gases from cable sheath burns, using a two-sensor vacuum system without interrupting supply.
The Megger HVB10 is a high voltage bridge for accurate fault location on long HV cables — locating cable and sheath faults, sheath testing and pinpointing, with an automatic test sequence.
The Megger EZ-Thump 3 kV / 4 kV are highly portable low-voltage cable fault location systems with 500 J surge energy, for fast fault detection on shielded and unshielded cables.
The Megger EZ-Thump 12 kV is a compact portable cable fault location system with TDR, arc reflection (4/12 kV) and high-energy surge, using the Easy Go workflow for fast fault finding.
The Megger EZ-Restore Overdrive is a portable cable fault location system delivering a 1,100-joule surge at 12 kV, with optional DC breakdown-voltage testing for challenging cable faults.
The Megger digiPHONE+2 is a shock-wave (surge) receiver for acoustic and electromagnetic cable fault pinpointing, with up to 30 dB background-noise reduction.
The Megger R 30 is a powerful van-mounted cable fault location and diagnostic system for medium- and high-voltage cables. It combines ARM, decay, ICE, surge (2500 J) and VLF methods with a PLC-controlled HV plant, testing to 110 kV (400 kV optional) for prelocation and pinpointing of HV cable faults.
The Megger primeon is a fully automated, software-controlled cable fault location and diagnostics system for MV networks. It combines TDR, ARM, surge (thumper), VLF, tan delta and PD methods with motorised HV switching and a touchscreen, so faults are found and pinpointed quickly and safely.
The Megger Centrix 2.0 is a modern, powerful cable test van system for fast, non-destructive fault location up to 33 kV, combining VLF testing, PD diagnosis and a full suite of pre-location and pinpointing methods.
The Megger KC series test leads are long (30/60/100 m), 10 A-rated lead sets for continuity testing of lightning-protection conductors in wind turbines, on site or in manufacturing.
The Megger Digital Hydrometer Kit measures the specific gravity and temperature of flooded battery cells in five seconds, storing up to 1024 results with an 8-channel data logger.

Bench Multimeters